目的对肱骨远端髁间骨折3种内固定方法进行生物力学比较,为临床治疗提供理论依据。方法采用18具新鲜肱骨标本,制成远端“T”型髁间骨折损伤模型,用交叉克氏针加8字钢丝、“Y”型钢板、1/3管形钢板及重建钢板3种方法固定后,进行生物力学研究。结果在同等载荷条件下,1/3管形钢板及重建钢板固定效果最佳,“Y”型钢板次之,而交叉克氏针加8字钢丝刚度最差。结论1/3管形钢板及重建钢板固定牢固,稳定性好,优于其他内固定方法,但操作复杂,在临床上应当根据实际情况进行选择应用。
Objective A biomechanical comparison of three kinds of internal fixation for intercondylar fracture of humerus was, made so as to provide a theoretical basis for clinical practice. Methods 18 fresh humeri were used to reproduce T-type intercondylar fracture, and three different fixation appliances were applied, including cross Kirschner wire with addition of “8” wire, single “Y” type plate, 1/3 tubular plate with reconstruction plate. Biomechanical tests were performed on these specimens. Result Under the same load condition, 1/3 tubular plate with reconstruction plate yielded the best results, while crossing Kirschner wire with “8” wire was the poorest. Conclusion The results showed that 1/3 tubular plate with reconstruction plate was a good internal fixation appliance. It has a proper design and stability, but it is not easy to apply. Therefore, an optimal method should be chosen according to local condition in clinical practice.
出处
《解放军医学杂志》
CAS
CSCD
北大核心
2005年第4期339-341,共3页
Medical Journal of Chinese People's Liberation Army
关键词
肱骨髁间骨折
内固定
生物力学
intercondylar fracture of humerus
internal fixation
biomechanical study