期刊文献+

FY-2多通道扫描辐射计的可见光外场定标 被引量:2

Visible outfield calibration for FY-2 multi-channel scan radiometer
下载PDF
导出
摘要 可见光定标是FY-2气象卫星多通道扫描辐射计研制的关键技术之一,发射前的精确定标是气象资料定量化和数字化应用的主要依据。基于Beer定理,详细说明定标的原理,摸索出一套适合于FY-2扫多通道描辐射计的可见光外场定标方法,建立起定标的规范程序,并对误差来源进行了分类和分析。通过在昆明的多次外场试验,获取了良好的定标结果,验证了这一方法的正确可行。 Visible calibration is one of the key technologies for multi-channel scan radiometer (MCSR) on FY-2 geostationary meteorological satellite. Accurate pre-launch calibration is the base and foundation for applications of meteorological information. According to the Beer principle, a set of technique and process fit for FY-2 MCSR are provided and set up to accomplish the outfield visible calibration in Kunming. We also analyze the error and tolerance sources to substantiate and improve our experiment data, which validates that all results are credible and satisfied.
出处 《量子电子学报》 CAS CSCD 北大核心 2005年第2期295-298,共4页 Chinese Journal of Quantum Electronics
关键词 辐射度学 多通道扫描辐射计 Beer定理 可见光定标 radiometry multi-channel scan radiometer(MCSR) Beer principle visible calibra- tion
  • 相关文献

参考文献7

  • 1.在轨卫星传感器绝对辐射定标[B].国家卫星气象中心大气辐射室,1994..
  • 2McCartney E J. Optics of the Atmosphere-scattering by Molecules and Particles [M]. Beijing: Science Press, 1988.(in Chinese).
  • 3Han Xinzhi, Jiao Shiju. Optical Remote Sensing Radiometry From Earth Orbiting Spacecraft [M]. Harbin: Harbin Institute of Technology Press, 1994. (in Chinese).
  • 4Wu Haoyu, et al. Research of Field Optics Measurement Instrument Applied in Calibration [C]∥ Beijing: Ocean Press, 2001. (in Chinese).
  • 5Zheng Xiaobing, et al. Highly Accuracy Primary and Transfer Standards for Radiometric Calibration [C]∥ Beijing:Ocean Press, 2001. (in Chinese).
  • 6Thome K J, Whittington E E, et al. Ground-reference Techniques for the Absolute Radiometric Calibration of MODIS [C]∥ Proc. SPIE, 2000, 4135: 60-70.
  • 7Anderson N, et al. Bi-directional Calibration Results for the Cleaning of SpectralonTM Reference Panels [C]∥Proc. SPIE, 2002, 4814: 201-210.

同被引文献26

  • 1王敏,何明元,张水平,陈晓颖,邱敏.通道式可见光近红外卫星遥感器辐射定标方法综述[J].遥感信息,2014,29(1):114-120. 被引量:11
  • 2相里斌,袁艳.单边干涉图的数据处理方法研究[J].光子学报,2006,35(12):1869-1874. 被引量:36
  • 3周磊,彭妮娜,张黎明,吴浩宇,郑小兵.基于标准探测器的FY-2(05)星扫描辐射计可见通道外场定标[J].遥感技术与应用,2007,22(1):20-25. 被引量:6
  • 4J.B.Rafert,R.G.Sellar,J.Blatt.Monolithic Fourier transform imaging spectrometer [J].Appl.Opt.,1995,34(31):7228-7230.
  • 5E.M.Granger.A calibration method for radiometric and wavelength calibration of a spectrometer[C].SPIE,1998,3648:237-241.
  • 6K.J.Thome,E.E.Whittington,N.Smith et all..Ground-reference techniques for the absolute radiometric calibration of MODIS [C].SPIE,2000,4135:60-70.
  • 7N.Anderson,F.Biggar Stuart,Burkhart Charles et al..Bi-directional calibration results for the cleaning of spectralon reference panels [C].SPIE,2002,4814:201-210.
  • 8Qiu Jinhuan,Yang Liquan.Broadband radiation methods to determine aerosol optical depth and imaginary part of its refractive index and their applications[J].J.Appl.Meteorol.,2003,42(11):1611-1625.
  • 9T.R.Gentile,J.M.Houston,J.E.Hardis et al..The NIST high accuracy cryogenic radiometer[J].Appl.Opt.,1996,35(7):1056-1068.
  • 10D.L.Smith.J.Delderfield.D.Drummond.T et al..Pre-launch calibration of the advanced along track scanning radiometer(AATSR)[C].SPIE,1999,3870:377-388.

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部