原电池滥用试验装置的研制

Development of the misuse test equipment for primary batteries
下载PDF
导出
摘要 国际标准IEC60086-5中介绍了原电池的可预见性误用试验(即滥用试验)及试验步骤。滥用试验包括外部短路试验、强制逆向试验、过放电试验。为保证检测人员的人身安全,方便检测,研制出一种综合性试验装置,且确保了检测精度。运行结果表明,该装置安全、可靠,简单易操作。 The foreseeable misuse test(viz. abuse test).which consists of exter nal short circuit test, incorrect installation test and over-discharge test, as well as the test procedure, are introduced in IEC 60086-5. In order to carry o n abuse test, and insure the operator's safety, an integrated test equipment is developed. It is controlled by computer, and has good precision. It is improved that the equipment is safe, reliable and easy to operate.
作者 任鉴民
出处 《电池工业》 CAS 2005年第2期90-92,共3页 Chinese Battery Industry
关键词 原电池 滥用试验 外部短路 强制逆向试验 过放电 primary batteries misuse test external short circuit incorrect i nstallation test over-discharge
  • 相关文献

参考文献3

  • 1IEC60086-5, Primary batteries Part5: Safety of batteries with aqueous electrolyte[S]. 2000.
  • 2丁志刚 李刚民.单片微型计算机原理[M].北京:电子工业出版社,1996..
  • 3林言端.DJX型电池自动放电屏的研制[J].电池工业,1999,4(1):14-16. 被引量:2