电流差动保护两种优良制动特性的分析比较 被引量:2

Analysis and Comparison of Two Excellent Restraining Characteristic of Pilot Current Differential Protection
下载PDF
导出
摘要 利用相位特性分析法和幅值特性分析法对复合式动作判据和自适应方向纵差保护动作判据进行了分析比较,两种动作判据都具有优良的制动特性。对这两种动作判据在两侧电流不同取值及内部故障和外部故障等不同情况下分别进行详细的分析,可知自适应方向纵差保护动作判据优于复合式动作判据。 Compound pilot current differential operating criterion and adaptive directional pilot current differential operating criterion, a new operating criterion,are analysed and compared in this paper using phase characteristic analytical method and magnitude characteristic analytical method. Both operating criteria possess excellent restraining characteristic. Compound operating criterion and adaptive directional pilot current differential protective operating criterion are analysed respectively in detail when electric currents in two ends are different in case of all internal faults and external faults. The analysis given in the paper show that the adaptive directional pilot current differential protective operating criterion is better than the compound criterion.
出处 《电力系统及其自动化学报》 CSCD 北大核心 2005年第2期1-4,12,共5页 Proceedings of the CSU-EPSA
关键词 电流纵差保护 制动特性 自适应原理 pilot current differential protection operating characteristic adaptive principle
  • 相关文献

参考文献3

  • 1葛耀中.电流差动保护动作判据的分析和研究.西安交通大学学报,1980,14(2):93-107.
  • 2罗姗姗,张源会.一种分相式电流差动微波保护新判据[J].电力系统及其自动化学报,1995,7(1):49-58. 被引量:2
  • 3贺家李 薛士敏 郭征.输电线微机自适应分相纵差保护方法[P].中国专利:ZL2004100190040..