阐述了娘子关发电厂化学水处理设备状况,分析了除盐设备周期制水量偏低酸碱耗偏高的问题,对该厂中间排水装置进行了改造,使该厂一级除盐水系统周期制水量大大提高,降低了发电成本,取得了较大的经济效益和社会效益。
The situation of chemical water treatment equipment in Niangziguan electric power plant was introduced, the problems that the cyclic water-treated quantity of demineralization plant was slightly less and the consumption of acid & alkali was slightly higher than expectation were analyzed, based on the analysis above, the improvement of intermediate discharge water device was done, making the cyclic water-treated quantity of the primary desalted water system higher, reducing the cost of power generating, gaining a lot of economic and social benefit.
出处
《黑龙江电力》
CAS
2005年第2期137-138,共2页
Heilongjiang Electric Power
关键词
除盐设备
中排间排水装置
改造
效益
demineralization plant
intermediate discharge water device
improvement
benefit