摘要 研究了稳流源对地电阻率观测系统可靠性的影响,从理论上分析了稳流源输出电流的稳定性与系统测量数据可靠性之间的联系;从技术上分析了用于稳流源的高频开关技术和多种可靠性技术对观测系统长期可靠的重要性。理论分析阐述了稳流源输出电流稳定的意义,新技术的采用促进了地电观测系统设计技术的提高。 In this paper we studied the reliability of apparent resistivity measuring system associated with the current supply, theoretically analyzed the effect of varying output of current supply on the system data reality, and suggested the design plans of regulated current instrument of apparent resistivity using high frequency switching technology and some reliable technology. The theoretic analysis shows the importance of constant output of regulated current supply. And the application of new technology can improve the reliability of the system.
出处 《地震研究》 CSCD 北大核心 2005年第2期202-206,共5页 Journal of Seismological Research
基金 国家自然科学基金项目(40474027)资助.
关键词 稳流源 地电阻率 观测系统 可靠性 高频开关技术 regulated current supply, apparent resistivity, reliability, high frequency switching technology
  • 相关文献

参考文献2

二级参考文献6

  • 1赵家骝 汤树芬 等.形变电阻率测量用可控硅稳流电源的设计及其性能[J].西北地震学报,1979,1(3):81-85.
  • 2沙占友,新型特种集成电源及应用,1998年
  • 3毛楠,电子电路抗干扰实用技术,1996年
  • 4王水平,开关稳压电源——原理、设计与使用电路,1997年
  • 5国家地震局科技监测司,地震电磁观测技术,1995年
  • 6赵家骝,西北地震学报,1979年,1卷,3期,81—85页

共引文献5

同被引文献38

  • 1孙承德,顾贞庆,钟国芬.深井电阻率所处井孔位置与地震关系的研究[J].西北地震学报,1996,18(4):74-76. 被引量:4
  • 2王帮本 刘永兰 李验轩.深井电阻率与地震预报.地震研究,1981,4(4):398-403.
  • 3国家地震局.1986.地电台站观测技术规范[M].北京:地震出版社.
  • 4孙正江;王华俊.地电概论[M]北京:地震出版社,1984187-192.
  • 5钱家栋;陈有发;金安忠.地电阻率法在地震预报中的应用[M]北京:地震出版社,1985226-266.
  • 6钱家栋;顾左文;赵家骝.地震台站观测环境技术要求第2部分:电磁观测[S]北京:中国标准出版社,200414-29.
  • 7杜学彬;席继楼;谭大诚.地震台站建设规范地电台站第1部分:地电阻率台站[S],20062-5.
  • 8张秀霞;李飞;杨冯威.蔬菜大棚对新沂地震台地电阻率的影响[J]地震地磁观测与研究,2009(增):32-36.
  • 9张新基;赵仪全;刘耀炜.甘肃省地震监测志[M]兰州:兰州大学出版社,2005.
  • 10谭大诚.地电观测中工频干扰的分析[A]兰州:兰州大学出版社,1998176-183.

引证文献4

二级引证文献70

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部