摘要
针对河坡发电有限责任公司存在的结焦问题,主要介绍了冷、热态燃烧调整所做的工作,分析了结焦原因,并给管理和运行提出了一些建议。
The paper deals with problems of Hepo Power Generating Co.,Ltd which existed in slagging.Combustion adjustment test for cold and hot functional test has been introduced in the paper,and analysed the reason of slagging.Thus makes some suggestion for management and operating.
出处
《山西电力》
2005年第2期14-15,19,共3页
Shanxi Electric Power