摘要
文章根据国内外600MW机组的工程设计资料,介绍了接地变压器参数选择的基本原则和计算方法,并通过对工程实例的分析,核校了该工程600MW发电机中性点接地变压器有关设备参数,并归纳该设备的统一参数、选择方法和规范,以便在相近的工程中做到规范统一。
According to project design information of 600 MW unit both in domestic and abroad, the basic principles and calculation methods for parameter selection of grounding transformer were introduced. Through the analysis of project example, the relevant equipment parameters of grounding transformer for 600 MW unit were checked, and the specification, selection method and the unified parameter of the equipment were summarized in order to accomplish the unified standard and specification in similar projects.
出处
《电力设备》
2005年第4期34-37,共4页
Electrical Equipment
关键词
发电机
中性点接地
变压器
参数分析
generator
neutral grounding
transformer
parameter analysis