本文针对某制药厂净化空调系统,分析讨论了原有系统存在的问题,介绍了系统技术改造的具体方案,通过改造前后测试数据的对比,说明了通过节能技术改造,不仅改善了车间的温湿度状况,同时实现了节能运行。
This paper discusses the problem of cleaning air-conditioning system in a pharmaceutical plant and introduces the methods of rebuilding system technically.Comparing with the measure data of the air-conditioning system before and after the system rebuilding,it is demonstrated that the system rebuilding not only improves the temperature and the humidity of the workshop ,but also achieves the goal of saving energy.
出处
《制冷》
2005年第1期39-42,共4页
Refrigeration
关键词
净化空调系统
节能
改造
双速电机
Cleaning air-conditioning system,Energy saving,Rebuilding,Two-speed motor