对某厂房轴流风机叶片断裂的原因进行了分析,探讨了系统对该风机的性能影响,从而制定了切实可行的措施,使该风机安全运行。
Analysis on the reason of impeller fracture of axial-flow fans in this building is introduced, and the influences of the system on the performances of this fan is investigated so that the feasible measures can be established to ensure safely operation of the fan.
出处
《流体机械》
CSCD
北大核心
2005年第4期47-49,46,共4页
Fluid Machinery
关键词
轴流风机
叶片断裂
不稳定工况区
axial-flow fan
impeller fracture