摘要
泗阳第二抽水站的主机泵在安装过程中出现电机大轴弯曲,摆度严重超标等问题。通过对大轴弯曲部位的火焰矫正,顺利地解决了上述问题,该方案不仅为该站机泵安装提供了技术数据的支持,同时也为泵站安装过程中同类问题的出现提供了解决思路,具有一定的参考价值。
The flame-rectify technique is designed to solve the problem as to the bending of the great axes and the large cone-degree. the problem has been settled all right .The result not only provides the necessary basis for fixing the electromotor and pump of the Siyang second pumping station, it also has the function of guiding and referring for the similar pumping station valve.
出处
《机电工程技术》
2005年第5期89-90,共2页
Mechanical & Electrical Engineering Technology
关键词
火焰矫正
弯曲
应力
摆度
flame-rectify
bend
stress
cone-degree