摘要 研究将Douglas Carroll UEFT进行修订并进行信度和效度检验.从19名病人的资料中获得初步结果.UEFT的再测信度检验显示该表高度稳定(R=0.99,P<0.01);与Barthal指数有关上肢功能的项目和手臂稳定度等测量有较高的相关(R=0.70,R=0.84,P<0.01),在临床上,UEFT与WHO分级和Brunnstrom分级也高度相关(R=-0.95,R=0.89,P<0.01).研究表明UEFT确具有使用简便、实用、准确的优点,在治疗过程中能反映上肢功能的改变情况,为上肢功能诊断和评估提供了一种可靠的手段. This is a study to examine the reliability and validity of a revised Douglas Carroll Upper Extremity Function Test (UEFT). Preliminary result was obtained from 19 patients. A reliability re-test of UEFT showed that the test is highly reliable (R = 0. 99, P<0. 01). This is highly correlated with the upper extremity and arm stabillity subtests of Barthel index (R = 0. 70, R = 0. 84, P<0. 01). It is also highly correlated with WHO classification and Brunnstrom classification (R= -0. 95, R = 0. 89, P<0. 01). This study showed that UEFT has the advantages of being simple, practical and precise. It can be a reliable test reflecting the changes of upper extremity during clinical rehabilitation treatment in diagnosing and evaluating upper extremity functions.
机构地区 中山医科大学
出处 《中国康复》 1994年第4期172-174,共3页 Chinese Journal of Rehabilitation
关键词 上肢功能测量 信度 效度 康复 upper extremity function test reliability validity