期刊文献+

胰岛素泵的研究及对人工胰腺发展的展望 被引量:5

Research situation of insulin infusion pump and trend of artificial pancreas
下载PDF
导出
摘要 随着生活水平的提高,中国糖尿病的患者增长率呈上升趋势。为克服传统治疗方法的局限性,对目前已投入应用的胰岛素泵的技术进行了介绍,并分析胰岛素泵研究的最新成果和微系统领域在相关方面的最新进展,对人工胰腺的发展进行展望。 The number of diabetic patients in China has kept growing with the improving living standards. Since the limitations of the traditional medicine and therapies for diabetes are seen more and more obviously in order to eliminate them the future prospects of artificial pancreas are described in the paper based on the techniques of insulin infusion pump which has put into practice lately and the latest development of MEMS as well as the newest advancement on diabetes researches.
出处 《国外医学(生物医学工程分册)》 2005年第2期98-101,127,共5页 Foreign Medical Sciences(Biomedical Engineering Fascicle)
关键词 胰岛素泵 人工胰腺 糖尿病 insulin infusion pump artificial pancreas diabetes
  • 相关文献

参考文献20

  • 1McD Schetky L, Jardine P, Moussy F. A closed loop implantable artificial pancreas using thin film nitinol MEMS umpsproceedings [A].Int Conf Shape Memory and Superelastic Technologies(SMST-2003 )[C ]. California: Pacific Grove, 2003.
  • 2Shichiri M, Kawamori R, Yamasaki Y, et al. Wearable artificial endocrine pancreas with needle-type glucose sensor[J]. Lancet, 1982,2: 1129-1131.
  • 3Renard M. An artificial pancreas without the need for injections found safe and effective [ R ]. 62nd ADA Ann Meeting. The News letter for Professionals in Diabetes Care. USA: San Francisco, 2002.
  • 4沈阳安姆医疗技术发展有限责任公司.智能型胰岛素泵的传动机构[P].中国专利CN00210385.0.2001-08-01.
  • 5郝力.胰岛素泵[P].中国专利CN 99255511.6.2000-09-20.
  • 6Silverstein JH, Rosenbloom AL. New development in type 1 (insulin dependent) diabetes[J]. Clin Pediatr, 2000, 39: 257-266.
  • 7Mastrototaro J. The minimed continuous glucose monitoring system(CGMS) [ J ]. J Pediatr Endocrinol Metab, 1999, 12:751-758.
  • 8Malin SF, Ruchti TL, Blank TB, et al. Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy[J]. Clin Chem,1999, 45(9): 1651-1658.
  • 9Chassin LJ, Hovorka R ,Wilinska ME. Assessing the effect of delay in glucose sampling on closed-loop glucose control: A simulation study diabetes[R]. UK's 2002 Ann Prof Conf. UK: Birmingham, 2002. 13-15.
  • 10Chassin LJ, Hovorka R, Wilinska ME. Simulation with 40 min delay in glucose measurements demonstrates feasibility of a closed loop control using subcutaneous measurement and subcutaneous insulin infusion [A]. ADA's 62nd Scientific Sessions (American Diabetes Association) 2002[C]. USA: San Francisco,2002. 14-18.

同被引文献50

引证文献5

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部