简述了目前在国内电厂使用较为普遍的瑞士产“8891”型在线硅表运行中经常遇到的普遍性问题和处理办法,介绍了在解决硅表的运行、维护、试剂配制中常见问题的经验和体会。
This paper simply discuss the common problem often met during operation o f“8891”type on -line silicon meter produced in Swiss which is widely use d in our country and treatment method,and elaborate experience and feeli ng to silicon meter of the problem such as operatio n,mainenance and reagent make -up etc.
出处
《江西电力》
2005年第2期46-47,共2页
Jiangxi Electric Power
关键词
火电厂
化学
在线仪表
监测
二氧化硅表
处理方法
power plant
chemistry
on -line meter
monitoring
silica meter