摘要 现场检测建筑物围护结构的热阻对于贯彻国家的建筑节能法规有重要意义。本文提出采用热箱法检测建筑物围护结构的热阻以解决非采暖季进行检测的问题。利用所建立的传热模型和数值计算软件,通过对热箱法现场检测建筑物围护结构热阻时由于侧向热流引起误差的分析,讨论了各参数对这种测试方法的影响;研究表明该方法是可行的,但应对侧向热流引起的误差给予足够的重视,必要时应采取适当措施加以修正。 In-situ measurement of the thermal resistance of building enclosures is of great significance to implement the national code of energy conservation in buildings. In this paper the hotbox method was devised for measurements of thermal resistance of building enclosures in non-heating seasons. A heat conduction model was established,which was solved by numerical simulation software.The errors caused by lateral heat losses in measurements were analyzed. Influences of various parameters on the measurement precision were discussed accordingly.The study showed that the proposed hotbox testing procedure is feasible for in-situ supervision of building enclosures while adequate attention is paid to the errors of lateral heat loss, and appropriate corrections may be necessary.
出处 《建筑热能通风空调》 2005年第2期74-77,80,共5页 Building Energy & Environment
关键词 围护结构 现场检测 建筑物 热箱法 热阻 数值计算软件 节能法规 传热模型 测试方法 误差 热流 侧向 energy conservation, heating, thermal resistance, measurement, error analysis
  • 相关文献

参考文献3

  • 1.采暖居住建筑节能检验标准(JGJ132-2001)[S].北京:中国建筑工业出版社,2001.28-37.
  • 2.居住建筑节能设计标准(山东省工程建设标准)(DBJ14-022-2003)[S].北京:中国建筑工业出版社,2003.12-17.
  • 3ANSYS公司.ANSYS热分析指南[Z].,1998,12.1-18.

共引文献1

同被引文献13

  • 1ASTM C1363-97 ,Standard Test Method for Steady-State Thermal Performanee of Building Assemblies by Means of a Guarded Hot Box,American Society for Testing and Materials, 1997.
  • 2ANSYS公司.ANSYS热分析指南[Z].,1998,12.1-18.
  • 3(JGJ132—2001)[S].中华人民共和国行业标准:《采暖居住建筑节能检验标准》.[S].,2001..
  • 4(DBJ14-022—2003)[S].山东省工程建设标准:《居住建筑节能设计标准》.[S].,2003..
  • 5ASTM C1363-97, Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box [S]. American Society for Testing and Materials, 1997.
  • 6JGJ132-2001.采暖居住建筑节能检验标准[S].
  • 7DBJ14-022-2003,居住建筑节能设计标准[S].
  • 8GAO Y.,ROUX J J.,Reduced Linear State Mode of Hollow Blocks Walls,Validation Using Hot Box Measurements[J].Energy and Buildings,2004,(36):1107-1115.
  • 9ASTM C1363-97,Standard Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box[C].American Society for Testing and Materials,1997.
  • 10沈意成,李根,杨俊俊,张辉.主动式建筑能耗检测的理论和实验研究[J].建筑热能通风空调,2010,29(1):83-86. 被引量:2