摘要 圆锥角膜是一种非炎症性进展性结缔组织疾病,主要表现为角膜的变薄及前突。透气性硬性接触镜(RGPCL)可用于大多数圆锥角膜患者的视力矫正。随着RGPCL材料及设计方式的层出不穷,RGPCL验配方法的推陈出新,成功地为圆锥角膜进行验配成为一项极具挑战性的工作。根据角膜形状选择个性化的镜片设计,运用优化的“三点接触式”验配原则,大多数患者将获得满意的镜片配适。当然,成功验配必须包括满意的矫正视力,充足的戴镜时间,配戴舒适及安全。 · Keratoconus is a progressive, non-inflammatory connective tissue disorder that causes central corneal thinning and ectasia. RGP lens can help to improve mostof the patients'visual acuity. Nowadays, with the invention of new material andthe emergence of various ways to design the lens, we have more options for RGP fitting approaches. The best choice for the patients is trying to improve their visual acuity and keep the eyes safe and comfortable. The 'three-point-touch' approach is now the most widely-accepted corneal lens fitting technique in clinical practice.·
作者 张琼 谢培英
出处 《国际眼科杂志》 CAS 2005年第2期313-317,共5页 International Eye Science
关键词 硬性接触镜 圆锥角膜 透气性 矫正技术 RGPCL 结缔组织疾病 主要表现 视力矫正 设计方式 验配方法 镜片设计 矫正视力 戴镜时间 配戴舒适 进展性 炎症性 个性化 接触式 患者 keratoconus rigid gas permeable contact lens (RGPCL) DK value 'three-point-touch' approach apical bearing apical clearance
  • 相关文献

参考文献23

  • 1谢培英,成颖,刘悦.接触镜对101例圆锥角膜的矫正与治疗[J].眼视光学杂志,1999,1(1):19-23. 被引量:40
  • 2徐思毅,吕帆.配戴接触镜后角膜敏感性改变的研究进展[J].国际眼科杂志,2004,4(2):324-326. 被引量:8
  • 3Zadnik K, Barr JT. Diagnosis, contact lens prescribing and care of the keratoconus patient. In: Lowther GE, Leahy CD, eds., Clinical Practice in Contact Lenses. Oxford: Butterworth-Heinemann, 1999.
  • 4Saini JS, Saroha V, Singh P, Sukhija JS, Jain AK. Keratoconus in Asian eyes at a tertiary eye care facility. Clin Exp Optom, 2004;87(2):97-101.
  • 5Rabinowitz YS, Nesbern AB, McDonnell PJ. Videokeratography of the fellow eye in unilateral keratoconus. Ophthalmology, 1993;100:181-186.
  • 6Phillips AJ. Can true monocular keratoconus occur? Clin Exp Optom,2003;86(6):399-402.
  • 7夏元,黄振平.圆锥角膜的研究进展[J].医学研究生学报,2003,16(11):850-851. 被引量:4
  • 8Kanski JJ. Clinical Ophthalmology: a Systemic Approach. 3rd ed. London:Butterworth-Heinemann, 1994:138-143.
  • 9李红.圆锥角膜一家系[J].中国中医眼科杂志,2000,10(1):25-25.
  • 10Wang Y, Rabinowitz YS, Rotter J, Yang H. Genetic epidemiological study of keratoconus: evidence for a major gene determination.American Journal of Medical Genetics, 2000;93:403-409.

二级参考文献34

  • 1Brennan NA, Bruce AS. Esthesiometry as an indicator of corneal health.Optom Vis Sci, 1991;68(9):699-702
  • 2Knoll HA, Williams J. Effects of hydrophilic contact lenses on corneal sensitivity. Am J Optom Arch Am Acad Optom, 1970;47(7):561-563
  • 3Millodot M. Effect of soft lenses on corneal sensitivity. Acta Ophthalmol (Copenh), 1974;52(5):603-608
  • 4Beuerman RW, Rozsa AJ. Threshold and signal detection measurements of the effect of soft contact lenses on corneal sensitivity. Curr Eye Res, 1985;4(6):742-744
  • 5Larke JR, Hirji NK. Some clinically observed phenomena in extended contact lens wear. Br J Ophthalnol, 1979;63(7):475-477
  • 6Hamano H. Topical and systemic influence of wearing contact lenses.Cantacto, 1960;4:41-48
  • 7Ko LS, Tomiyama SK. The influence of contact lens application on the corneal sensitivity. Trans Ophthal Soc Rep China , 1963;2:1-9
  • 8Sabell AG. Ocular changes in contact lens wearers. The Ophthal Optician,1968;8:1051-1057
  • 9Morganroth J, Richman L. Changes in the corneal reflex in patients wearing contact lens. J Pediat Ophthalmol,1969;6:207-208
  • 10Lydon DPM. Effect of rigid contact lens materials on the cornea and tear film of the human eye. PhD dissertation 1986 University of New South Wales.

共引文献47

同被引文献38

引证文献9

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部