摘要
HPLC法测定维生素E(微囊)硬胶囊与咀嚼片的含量,采用十八烷基键合相柱、甲醇流动相、检测波长285nm,两种制剂的回收率分别为99.32%和99.72%,相对标准偏差为0.58%和0.61%(n=5)。方法快速简便,准确可靠,重现性良好。测定结果表明,两种制剂稳定性良好。
A reversed-phase HPLC was used to assay the capsules and the chewable tablets of vitamin E microcapsules with Zorbax ODS column. The mobile phase was methanol, monitored by UV detector at 285nm. The mean recovery and RSD of the two preparations were 99.32%, 99.72% and 0.58%, 0.61%,respectively. The method was rapid, simple and reproducible. The stability of the two preparations was satisfactory after acceleration tests.