期刊文献+

HepG2肝癌细胞行为的PCC实时检测研究 被引量:2

Real-time PCC monitoring for behavior of living HepG2 liver cancer cells in vitro
下载PDF
导出
摘要 利用压电细胞芯片检测体系对HepG2肝癌细胞的行为进行24h实时监测,得出典型响应曲线,结合组织培养板进行的模拟对照实验和HepG2肝癌细胞的生长特性,将响应曲线分为游离期、黏附期、平台期3个行为时段,并分析和计算在各行为时段的基本特性和平均用时;还利用双胰酶法计算出电极表面的细胞平均贴壁率为76.8%。结果反映了PCC检测信号与细胞行为的对应性及利用PCC探索细胞行为及影响因子的可行性,并验证了PCC技术检测细胞行为的快速和灵敏性能。 A new method combining piezoelectric biochip technique with cell culture technique in vitro is developed. Piezoelectric Cell-Based Chip (PCC) can continuously monitor the behaviors of living cancer cells by detecting the shift of the resonant frequency, Δf, of the oscillating system. In this paper, the studies of HepG2 liver cancer cells using PCC technique are reported and graphed, thus a typical response curve appears. The curve is divided into such three phases based on the growth properties of the cells as the ones of dissociation, attachment and plateau. The time spans and characteristics of the phrases are analyzed and the average attaching rate is proved to be 76.8% by double trypsin assay. The experiments reveals the correspondence ofΔf to cell behaviors and the applicability of PCC to detecting cell behaviors and influencing factor. The PCC proves to be a potential tool in R&D and clinical application.
出处 《医疗卫生装备》 CAS 2005年第6期11-12,37,共3页 Chinese Medical Equipment Journal
关键词 PCC HEPG2肝癌细胞 细胞行为 PCC HepG2 liver cancer cell cell behavior
  • 相关文献

参考文献11

  • 1Abe, Takashi, et al. Energy dissipation in small-diameter quartaz crystal microbalance experimentally studied for ultra-high sensi tive gravimetry. IEEE, 2003(1) :518~521.
  • 2姚守拙.非质量效应压电化学传感的应用与发展[J].化学通报,2001,64(9):533-536. 被引量:7
  • 3Wegener J.Analysis of the Composite Response of Shear Wave Resonators to the Attachment of Mammalian Cells. Biophys J,2000,78(6):2821~2833.
  • 4Zhou T. The quartz crystal microbalance as a continuous monitoring tool for the study of endothelial cell surface attachment and growth. Biotechnology Progress, 2000,16(2):268~277.
  • 5Voinova M V, Jonson M, Kasem B. 'Missing mass' effect in biosensor's QCM application. Biosensors and Bioelectronics, 2002,17(1 ):835~841.
  • 6kenneth A M. Quartz crystal microbalance study of endothelial cell number dependent differences in initial adhesion and steadystate behavior: evidence for cell-cell cooperativity in initial adhe sion and spreading. Biotechnol. Prog, 2003,19(3):987~999.
  • 7Reiss, Bjorn. Adhesion kinetics of functionalized vesicles and mammalian cells: A comparative study. Langmuir, 2003,19(53):1816~1823.
  • 8Sota, Hiroyuki. A versatile planar QCM-based sensor design for nonlabeling biomolecule detection. Analytical Chemistry, 2002,74(15):3592~3598.
  • 9Reimhult E. Vesicle adsorption on SiO2 and TiO2: Dependence on vesicle size. Journal of chemical physics,2002,117(16):7401~7404.
  • 10Andersson, Kasemo B. Cell adhesion on supported lipid bilayers.Journal of Biomedical Materials Research-Part A,2003,64(4):622-629.

二级参考文献1

共引文献6

同被引文献23

  • 1余元龙,季明芳,何洁冰,李晓玲.紫杉醇对肝癌细胞增殖抑制和诱导凋亡的效应研究[J].中华实验外科杂志,2004,21(7):877-878. 被引量:6
  • 2Zhou T,Marx KA,Warren M,Schulze H,Braunhut SJ.The quartz crystal microbalance as a continuous monitoring tool for the study of endothelial cell surface attachment and growth.Biotech Prog,2000,16:268~277
  • 3Olofsson LGM,Edvardsson MEM,Delsing P,Kasemo B.Vesicle and bi-layer kinetics at surfaces measured by electrical transmission.Sensors and Actuators B,2004,97:313~318
  • 4张福学.现代压电学(上册).北京:科学出版社,2003
  • 5Rodahl M,Hook F,Krozer A,Brzezinski P,Kasemo B.Quartz crystal microbalance setup for frequency and Q-factor measurements in gaseous and liquid environments.Rev Sci Instrum,1995,66:3924~3930
  • 6Kanazawa KK,Gordon JG.Frequency of a quartz microbalance in contact with liquid.Anal Chem,1985,57:1770~1771
  • 7Martin SJ,Granstaff VE,Frye GC.Characterization of a quartz crystal microbalance with simultaneous mass and liquid loading.Anal Chem,1991,63:2272~2281
  • 8Lu C,Canderna AW.Applications of piezoelectric quartz crystal microbalances.New York:Elsevier,1984
  • 9Janshoff A,Galla HJ,Steinem C.Piezoelectric mass-sensing devices as biosensors:an alternative to optical biosensors? Angew Chem Int Ed,2000,39:4004~4032
  • 10Marx KA.Quartz crystal microbalance:a useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface.Biomacromolecules,2003,4:1099~1120

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部