摘要
用HPLC测定血浆中心律平的浓度,灵敏度高,准确度好,在50~4000ng/ml范围内线性关系良好,最低检测限50ng/ml。6名心律失常患者口服600mg心律平后,药时曲线拟合均呈一室模型,平均消除半衰期为2.3±0.6h,平均达峰时间3.0±0.7h,血浓最大个体差异相差7.9倍,峰浓最大相差2.5倍,提示心律平存在明显个体差异。
he methed for the determination of propafenone in plasma by high performance liquid chromatography was sensitive andaccurate. Analysis showed good agreement in the range of 50~4000ng/ml(regrssion coefficient=0.999).The detection li-mit for plasma propafenone was 50ng/ml.Propafenone showed one compartment medel after six arrhythmia patients were given propfenone 600mg,mean elimination half-life was 2.3±0.6h and was 3.0±0.7h,the maximum difference in plasmaconcentration was 7.3times. Cmax was 2.5times.It suggested significant individual difference.
出处
《中国医院药学杂志》
CAS
CSCD
北大核心
1994年第1期5-7,共3页
Chinese Journal of Hospital Pharmacy