摘要
采用JY-ULTIMA2型等离子光谱仪直接测定纯度99.8%~99.999%的氧化镥中的14种稀土杂质,选择了仪器的最佳工作条件。在选定条件下,14种稀土元素的检出限为0.04μg/g~2.5μg/g,对不同含量的氧化镥样品,加标回收率为93%~109%。方法简单、快速、准确,精密度好,已用于产品的检测。
A method for the determination of rare earth impurities in lutetium oxide has been developed.The operation condition of instrument was optimized working condition. The detection limits for 14 elements are 0.04~2.5μg/g.The method is accurate, rapid and convenient. It has been successfully applied to the determination of rare earth impurities in lutetium oxide samples with satisfactory results.
出处
《稀土》
EI
CAS
CSCD
北大核心
2005年第3期64-67,共4页
Chinese Rare Earths