期刊文献+

A novel access method for endovascular procedures in the porcine model

A novel access method for endovascular procedures in the porcine model
下载PDF
导出
摘要 Objective To evaluate the use of the saphenous artery as an alternative access for endovascular procedures in the porcine model. Methods Fourteen adult pigs (25-35 kg) were used in this study, 3 pigs from an acute study and 11 from chronic studies. A 2-3 cm incision was made and a saphenous artery cutdown was performed in 24 sides. Micropuncture sets (Boston Scientific) or 18 G puncture needles were used to access the artery. Different sizes of introducers (4-7 F) were used to establish endovascular access. Angiographic catheters were then used to confirm if the access was usable. Four saphenous arteries were explanted in the pigs from a chronic study 4 to 28 days after surgical procedure. Results The saphenous artery was very easy to expose and 4-5 F introducer sheaths were able to be inserted to establish access for endovascular procedures in the pigs. The saphenous artery was unable to accomodate an introducer with a size larger than 6 F. Four saphenous arteries were injured when 5 and 6 F introducers were used, but angiographic procedures could still be performed. Morphologic evaluation of the explanted arteries demonstrated occlusion of the saphenous arteries without injury or disruption of the adjacent femoral arteries. Conclusion The saphenous artery can be used as an access site in pigs for angiographic and interventional procedures if the catheter size is less than 6 F. This vessel is easier to access and can preserve the femoral artery for repeat procedures in the future. Objective To evaluate the use of the saphenous artery as an alternative access for endovascular procedures in the porcine model. Methods Fourteen adult pigs (25-35 kg) were used in this study, 3 pigs from an acute study and 11 from chronic studies. A 2-3 cm incision was made and a saphenous artery cutdown was performed in 24 sides. Micropuncture sets (Boston Scientific) or 18 G puncture needles were used to access the artery. Different sizes of introducers (4-7 F) were used to establish endovascular access. Angiographic catheters were then used to confirm if the access was usable. Four saphenous arteries were explanted in the pigs from a chronic study 4 to 28 days after surgical procedure. Results The saphenous artery was very easy to expose and 4-5 F introducer sheaths were able to be inserted to establish access for endovascular procedures in the pigs. The saphenous artery was unable to accomodate an introducer with a size larger than 6 F. Four saphenous arteries were injured when 5 and 6 F introducers were used, but angiographic procedures could still be performed. Morphologic evaluation of the explanted arteries demonstrated occlusion of the saphenous arteries without injury or disruption of the adjacent femoral arteries. Conclusion The saphenous artery can be used as an access site in pigs for angiographic and interventional procedures if the catheter size is less than 6 F. This vessel is easier to access and can preserve the femoral artery for repeat procedures in the future.
出处 《中国介入影像与治疗学》 CSCD 2004年第2期147-150,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 异常通路方法 猪模型 静脉通路 《中国介入影像与治疗学》 Animal model, swine Angiographic, access Saphenous artery Less pain or stress, procedure
  • 相关文献

参考文献5

  • 1R. F. Dondelinger,M. P. Ghysels,D. Brisbois,E. Donkers,F. R. Snaps,J. Saunders,J. Devière.Relevant radiological anatomy of the pig as a training model in interventional radiology[J].European Radiology.1998(7)
  • 2Dondelinger RF,Ghysels MP,Brisbois D,et al.Relevant radiological anatomy of the pig as a training model in interventional radiology[].European Radiology.1998
  • 3Swindle MM.Swine as replacements for dogs in the surgical teaching and research laboratory[].Laboratory Animal Science.1984
  • 4Wright KC.Working with laboratory animals: general principals and practical considerations[].Journal of Vascular and Interventional Radiology.1997
  • 5Narayanaswamy M,Wright KC,Handarpa K.Animal models for atherosclerosis, restenosis, and endovascular graft research[].Journal of Vascular and Interventional Radiology.2000

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部