摘要 针对土壤源热泵地下垂直U型换热埋管,建立了周围土壤的非稳态温度场的数学模型,并利用隐式有限差分法进行了数值模拟。通过对制冷和制热工况的模拟,得到土壤温度沿径向的变化规律、埋管出水温度的变化规律及埋管的热作用半径的变化规律。 A transient heat transfer model of the soil temperature field around a vertical U-tube of ground source heat pump was established.The numerical simulation was obtained by using the implied finite difference method.By making the simulation of cooling and heating mode,the change rules of the soil temperature with the radial direction,the change rules of the exit water temperature of the buried pipe and the thermal influencing radius in the vertical multi-pipe were obtained.
出处 《节能》 2005年第6期6-9,2,共5页 Energy Conservation
  • 相关文献

参考文献6

  • 1Gu Y, O' Neal D L. Develpment of an equivalent diameter ea for vertical U-tubes used in ground-coupled heat pumps[J].ASHRAE Transactions, 1998, 104(2) :347 - 355.
  • 2Yavuzturk C., Spitler J. D., Rees S. J.. A transient Two-Dimensional finite volume model for the simulation of vertical U-Tube ground heat exchangers[J]. ASHRAE Transactions, 2001, 107(2) :617 - 625.
  • 3Deerman J. D., Kavanaugh S. P.. Simulation of vertical U-Tube Ground-Coupled heat pump systems using the cylindrical heat source solution [J]. ASHRAE Transactions, 1991,97(1) :287 - 295.
  • 4Yavuzturk C., Spitler J. D.. Field validation of a short time step model for vertical ground-loop heat exchangers [J].ASHRAE Transactions, 1999, 105(2) :465 - 474.
  • 5Cane R. L. D., Forgas A.. Modeling of ground source heat pump performance [J]. ASHRAE Transactions, 1991, 97(1):909 - 925.
  • 6史新慧,李素芬,卢立宁.套管式地下换热器研究[J].节能,2004,23(7):22-23. 被引量:4

二级参考文献5

共引文献3

同被引文献52

引证文献7

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部