期刊文献+

固体径迹图像分析法测量环境空气中氡浓度的研究 被引量:4

Investigation of image processing SSNTD and determination of radon in air
原文传递
导出
摘要 作者利用计算机图像识别技术,建立了测量环境空气中氧浓度测定的固体径迹图像分析方法,并在营房、坑道的氡水平调查中得到了应用.该方法与国家二级计量站标准氡室的比对结果为106.8±3.4Bq·m ̄(-3),和后期告知的标准氧暴露量115.6±4.3Bq·m ̄(-3),相对误差约为7.6%。测量速度较显微镜目测法有很大的提高,适合环境空气中氡浓度的测定和大规模氡水平调查。 An image processing solid statenuclear detector (SSNTD ) for radonsuryey has been deyeloped by usingcomputer technique of image discrim-mation' The method had good accuracy, i, e', the Rn concentration(106'8 t 3 '4 kBq .m- s .h ) determinedby this detector was in good accordance with the giyen exposure Yalue(115' 6 t 3' 4 kBq.m- s .h), and greatly increased measurement speed.It has been widely used in Rn inyestigation in hundreds of devillingsand galleries'
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 1994年第5期293-296,共4页 Chinese Journal of Radiological Medicine and Protection
关键词 固体径迹 探测器 图像分析 image processing radon
  • 相关文献

参考文献2

  • 1庞德聆,马国才,周智新.CSR环境氡监测器[J].核技术,1991,14(3):144-149. 被引量:6
  • 2方开泰.均匀设计——数论方法在试验设计的应用[J]应用数学学报,1980(04).

二级参考文献3

  • 1冯玉水,核技术,1988年,11卷,9期,44页
  • 2庞德聆,核技术,1988年,11卷,9期,4页
  • 3周智新,中华放射医学与防护杂志,1988年,8卷,4期,264页

共引文献5

同被引文献15

  • 1骆亿生,陈迪,于水,周郁,陶德元,何小海,赵英.全自动固体核径速测量系统[J].辐射防护,1996,16(4):264-270. 被引量:3
  • 2王燮华.环境空气中氡的水平[J].中国辐射卫生,1996,5(3):139-141. 被引量:11
  • 3UNSCEAR.电离辐射源与效应.UNSCEAR1993报告(中文本)[M].北京:原子能出版社,1995..
  • 4任天山,中华放射医学与防护杂志,1985年,5卷,5期,269页
  • 5李素云(译),ICRP 第50号出版物,1992年
  • 6FAO/IAEA/ILO/OECD-NEA/PAHO/WHO,IAEA安全丛书 No 115,1997年
  • 7地下建筑氡及其子体控制标准.GB16356-1996,1996年
  • 8于水,中华放射医学与防护杂志,1996年,16卷,5期,插页14页
  • 9UNSCEAR,UNSCEAR 1993报告,1995年
  • 10UNSCEAR 电离辐射源与效应 UNSCEAR 1993报告 (中文本 ),1995年

引证文献4