摘要
从人血清中提纯载脂蛋白A-Ⅰ(apoA-Ⅰ),制备抗apoA-Ⅰ抗血清,采用氯胺T法制备125I-apoA-Ⅰ,以平衡法建立apoA-ⅠRIA.灵敏度为51μg/L,检测范围0.1~12.8mg/L,批内CV6.2%,批间CV7.0%,效应误差关系0.019,回收率均值为98.9%,与人血清低密度脂蛋白交叉反应率小于0.095%.99例正常男、女性血清apoA-Ⅰ浓度分别为1.45±0.18g/L(±s)和1.42±0.19g/L,无明显性别差异(P>0.05).
Abstract Apolipoprotein A-Ⅰ(apoA-Ⅰ) was purified from human serum, and antiserum was obtained by immunizing rabbits. ApoA-Ⅰ was iodinated by chloramine-T method. A radioimmunoassay of apolipoprotein A-Ⅰ was developed.The sensitivity of the system was 51μg/L,with a working range of 0.1 ̄12.8mg/L.The intraassay CV and interassay CV were 6.2% and 7.0% respectively,the RER was 0.019,and the mean recovery rate was 98.9%.The serum apoA-Ⅰ level in 99 normal males and females was 1.45±0.18g/L(mean±s)and 1.42±0.19 respectively,with no significant sex difference.