摘要 目的:评价即时血流测量技术检测冠脉移植桥通畅性的应用价值.方法:在非体外循环心脏不停跳中行搭桥手术,术中应用即时血流测量仪测量移植桥流量,并对搏动指数和血流波形进行分析.结果:(1)不阻断竞争血流时无狭窄组和50%狭窄、75%狭窄组间的差异有统计学意义.无狭窄组和33%狭窄组血流波形是“舒张期优势型”,两组搏动指数低于标准搏动指数(PI=5).随着狭窄的加重,50%狭窄组、75%狭窄组桥血流波形变成以收缩期为主,出现高而尖的收缩期波形,舒张期波形低平;搏动指数大于5·0.(2)阻断竞争血流后各组的桥血流量明显上升.阻断竞争血流后50%狭窄组血流波形改善为舒张期优势型,搏动指数降至(3·02±0·94);而75%狭窄组桥血流波形仍然以收缩期为主,收缩期波形高而尖,舒张期波形低平;搏动指数大于5·0.结论:即时血流测量在冠状动脉搭桥术中可检测出≥75%的狭窄. Objective:To assess evaluate the accuracy of TTM to find out the stenosis of coronary artery anastomasis . Methods:Twelve adult healthy dogs of both sexes weighing (27.62±1.63)kg were anesthetized and their chests were opened with a medial sternotomy, There are four groups produced with four catheters divded in non-stenosis,33% stenosis,50% stenosis and 75% stenosis. Hemodynamic parameters including flow volume of graft,PI,wave of flow,heart rate(HR),blood pressure(BP),central venous pressure(CVP) were recorded . Results:(1) When there is a competitive flow, the flow volume of graft is less than the flow volume of graft which has not been affected by competitive flow in all four groups.(2) The flow volume of non-stenosis' graft is equare to 33% stenosis's, P<0.05. The flow volume of non-stenosis' graft is more than 50% stenosis's and 75% stenosis's, P<0.05.The flow volume of 33% stenosis is more than 50% stenosis's and 75% stenosis's, P<0.05.The flow volume of 50% stenosis' graft is more than 75% stenosis's, P<0.05.(3) When competitive flow have been occluded , the flow volume of graft of non-stenosis, 33% stenosis and 50% stenosis are more than 20mL/min. But the flow volume of graft of 75% stenosis is low. Conclusion Transit-time flow meter can provide a suitable measurement for intraoperative assessment of coronary graft patency.
出处 《昆明医学院学报》 2005年第2期54-58,共5页 Journal of Kunming Medical College
基金 广东省医学科学技术研究基金资助项目(WSTJJ20021110440102196512023239)
  • 相关文献

参考文献12

  • 1SPOONER T H, DYRUD P E, MONSON B K, et al. Coronary artery bypass on the beating heart with the octopns: a North American experience [J]. Ann Thorac Surg, 1998, 66 (3): 1032.
  • 2D ANCONA G, KARAMANOUKIAN H, RICCI M,et al. Graft patency verification in coronary artery bypass grafting: principles and clinical applications of transit time flow measurement [J]. Angiology, 2000,51:725.
  • 3BELDI G, BOSSHARD A, HESS O M, et al. Transit time flow measurement: experimental validation and comparison of three different systems [J ]. Ann Thorac Surg, 2000, 70:212.
  • 4JABER S F, KOENING S C, BHASKER - RAO B,et al. Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG. [J]. Ann Thorac Surg, 1998, 66:1087.
  • 5MARCO RICCI, HRATCH L KARAMANOUKIAN, et al. Role of coronary graft flow measurement during reoperations for early graft failure after off- pump coronary revascularization [J]. Card Surg, 1999, 14:342.
  • 6BARNEAL L, SANTAMORE W P. Intraoperative monitoring of IMAflow: what does it mean [J]. Ann Thorac Surg, 1997, 63:12.
  • 7ASCER E, VEITH FJ, MORIN L, et al. Components of outflow resistance and their correlation with graft patency in lower extremity arterial reconstructions[J]. Vasc Surg, 1984, 1:817.
  • 8ASCER E, WHITE S A, VEITH F J, et al. Outflow resistance measurement dunng I nfrainguinal arterial reconstructions: a reliable predictor of limb salvage[J]. AmJSurg, 1987, 4:185.
  • 9D' ANCONA G, KARAMANOUKIAN H, RICCI M, et al. Graft revision after transit time flow measurement in off - pump coronary artery bypass [ J ].Eur J Cardiothoral Sury, 2000, 17: 287.
  • 10D'ANCONA G, KARAMANOUKIAN H, SALERNO T A, et al. Flow measurement in coronary surgery[J]. Heart Sury Foram, 1999,2:121.

共引文献11

同被引文献25

  • 1Goldman S,Zadina K,Moritz T,et al.Long-term patency of saphenous vein and left internal mammary artery grafts after coronary artery bypass surgery:results from a Department of Veterans Affairs Cooperative Study.Am Coll Cardiol.2004;44(11):2149-2156.
  • 2Kawachi K,Kitamura S,Morita R,et al.Late results of coronary artery bypass grafting with the jnternal thoracic artery.Kyobu Geka.1992;45(8 Suppl):665-670.
  • 3William R,Burfeind Jr MD,Donald D,et al.Single versus multiple internal mammary artery grafting for coronary arter bypass:15-year follow-up of a clinicaI practice trial.Circulation.2004;110(1):1127-1135.
  • 4Rombaut E,Vantrimpont P,Gurne O,et al.Noninvasive functional assessment of left Internal mammary artery grafts by transcutanegus Doppler echocardiography.Am Sco Echocardiography.1998;11(8):403-408.
  • 5Calafiore AM,Gallina S,laco A.Minimally invasive mammary artery Doppler flow velocity evaluation in minimally invasive coronary operation.Ann Thorac Surg.1998;66:1236-1241.
  • 6Takami Y,Ina H.Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting.Ann Thorac Surg.2001;72(4):1 270-1 274.
  • 7Jaber SF,Koenig SC,BhaskerRao B,et al.Role of graft flow measurement technique in anastomotic quailty assessment in minimally invasive CABG.Ann Thorac Surg.1998:66(3):1087-1092.
  • 8D'Ancona G,Karamandian H,Ricci M,et al.Graft Patency verification in coronary artery bypass grafting:principles and clinical application of transit time flow measurement.Angiology.2000:51(9):72-731.
  • 9Canver CC,Cogler SD,Murray EL,et al.Clinical importance of measuring coronary graft flows in the revascularized heart.Ultrasonic or electromagnetic? Cardiovasc Surg.1 997;38:211-215.
  • 10Matre K,Birkeland S,Hessevik I,et al.Comparison of transit-time and Doppler ultrasoud methods for measurement of flow in aortocoronary bypass grafts during cardiac surgery.Thorac Cardiovasc Surg.1994:42(3):170-174.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部