摘要 目的研究on-lineHDF时应用高钠及超滤曲线是否对血压有影响。方法回顾性分析我院10名终末期肾衰竭(ESRD)患者的60例次HDF治疗,根据应用高钠与超滤曲线与否分成A、B两组(两组各30次),对两组患者行HDF时的1h、2h、3h、4h及最低血压进行比较。结果A、B组患者在其1h、2h、3h、最低血压比较差异有显著性,P<0.05。在其4h血压比较差异无显著性,P>0.05。结论结合高钠及超滤曲线可使患者进行HDF时血压平稳,比单纯行HDF的血流动力学更稳定。 Objective To study the influence of using high sodium and gradient ultrafiltration in on-line hemodiafiltration on blood pressure. Methods In a cross-section study,about 60 times on-line HDF of 10 ESRD patients were separated into two groups as group A:using high sodium and gradient ultrafiltration in on-line HDF(n=30) and group B:without using high sodium and gradient ultrafiltration in on-line HDF(n=30). Blood pressure of the 1st hour、2nd hour、3rd hour、4th hour and the lowest blood pressare in each group were compared between the two groups. Result There was significant difference of the blood pressure in the 1st hour、2nd hour、3rd hour and the lowest blood pressure between group A and group B (P<0.05). There was no significant difference of the 4th hour's blood pressure between the two groups. (P=0.293). Conclusion Using high sodium and gradient ultrafiltration in on-line HDF could make the blood pressure and hemodynamics more stable than in HDF without using.
出处 《中国血液净化》 2005年第5期254-256,共3页 Chinese Journal of Blood Purification
关键词 ON-LINE血液透析滤过 高钠 超滤曲线 血压 On-line hemodiafiltration High sodium Gradient ultrafiltration Blood Pressure
  • 相关文献

参考文献4

  • 1Vaslakic L, Weber C, Mitteregger R, et al.Cytokin induction in patientsunder going regula on-line hemodiafiltration treatment. Artif-Or-gans,2000,24(7):514-8
  • 2Canaud B,Bosc JY ,Stec F, et al.On-line haemodiafiltration:state of the art.Nephrol Dial Transplant,1998,13(Suppl 5):3
  • 3龚德华,季大玺.血液透析滤过技术的一些进展[J].肾脏病与透析肾移植杂志,2004,13(2):184-187. 被引量:38
  • 4Takenaka T, Tsuchiya, Suzuki H. High-performance hemodiafitration and blood pressure substitution fluid, Nephrol Transplant,1998,13(supple5):s29

二级参考文献23

  • 1龚德华,季大玺,谢红浪.高通量透析器复用的研究[J].医学研究生学报,2000,13(5):307-310. 被引量:26
  • 2龚德华,季大玺,谢红浪,徐斌,刘芸,黎磊石.连续性肾脏替代治疗剂量对溶质清除率的影响[J].中华内科杂志,2001,40(3):183-186. 被引量:17
  • 3Ronco C,Brendolan A,Crepaldi C,et al.Flow distribution and cross filtration in hollow fiber hemodialyzers.Contrib Nephrol.Basel,Karger,2002.120
  • 4Spalding E,Farrington K.Haemodiafiltration:current status.Nephron Clin Pract,2003,93:c87
  • 5Panichi V,Tetta C,Rindi P,et al.Plasma C-reactive protein is linked to backfiltration associated interleukin-6 production.J Am Soc Artif Intern Org,1998,44:M415
  • 6Marinez de Francisco AL,Ghezzi PM,Brendolan A,et al.Hemodiafiltration with online regeneration of the ultrafiltrate.Kidney Int,2000,76(Suppl):s66
  • 7Hauk M,Kuhlmann MK,Riegel W,et al.In vivo effects of dialysate flow rate on Kt/V in maintenance hemodialysis patients.Am J Kidney Dis,2000,35:105
  • 8Wizemann V,Kulz M,Techert F,et al.Efficacy of haemodiafiltration.Nephrol Dial Transplant,2001,16(Suppl 4):s27
  • 9Lornoy W,Becaus I,Billiouw JM,et al.Remarkable removal of beta2 -microglobulin by on-line hemodiafiltration.Am J Nephrol,1998,18:105
  • 10Brunet S,Leblanc M,Geadah D,et al.Diffusive and convective solute clearances during continuous renal replacement therapy at various dialysate and ultrafiltration flow rates.Am J Kidney Dis,1999,34:486

共引文献37

同被引文献12

  • 1叶朝阳.高通量血液透析的临床应用体会[J].肾脏病与透析肾移植杂志,2005,14(3):251-252. 被引量:32
  • 2Cheung AK, Levin NW,Greene T, et al. Effects of high-flux hemodialysis on clinical outcomes; results of the HEMO study [J].J AM Soc Nephrol,2003,14(12) :3 251-3 263.
  • 3Locatelli F, Martin-Malo A, Hannedouche T, et al. Effect of membrane permeability on survival of hemodialysis patients [J]. J Am Soc Nephrol,2009,20:645-654.
  • 4Amerling RCG, Dubrow A, Levin N, et al. Complications dur- ing hemodialysis. In: Nissenson A, Gentile D (eds). Clinical Dialysis[J]. Stamford, CT: Appleton Lange, 1995 : 236- 267.
  • 5Oaugirdas JT, Blake PG, Todd S. Handbook of dialysis. 3rd edn. Lippincott Williams Wilkins[J]. Hagerstown, MD; 2001.
  • 6Mona Doshi,Patrick T, Murray. Approach to intradialytic hy- potension in intensive care unit patients with acute renal failure[J]. Artificial Organs,2003,27 ( 9 ):772-780.
  • 7Silver SM, Desimone JA, Smith DA, et al. Dialysis disequilibri- um syndrome in the rat: role of the"reverse urea efect[J]. Kidney Int. 1992.42 : 161- 166.
  • 8Movilli E, Camerini C, Viola BF, et al. Blood volume changes during three different profiles of dialysate sodium varation with similar intradialytic sodium balances in chronic hemodialyzed patients[J]. Am J Kidney Dis, 1997,30 : 58.
  • 9Inrig JK, Oddone EZ, Hasselblad V, et al. Association of intra- dialytic blood pressure changes with hospitalization and mortal ity rates in prevalent ESRD patients[J]. Kidney Int, 2007,71 (5) :454-61.
  • 10Kerr PG, Sutherland WH, de Jong S, et al. The impact of standard high - flux polysulfone versus novel high - flux polysulfone dialysis membranes on inflammatory markers: a randomized,single-blinded,controlled clinical trial[J]. Am J Kidney Dis, 2007,49 : 533- 539.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部