摘要 在对比几种地源热泵系统U型埋地换热器的理论计算模型的基础上,将短时间步温度反应系数模型应用于某小区办公楼的地源热泵系统,对埋地换热器进行了理论分析,并给出了与实验值对比的结果.结果表明,短时间步温度反应系数模型可以较好地预测埋地换热器的换热性能,为地源热泵系统的设计与优化提供了依据. Based on the comparation of some theoretical models of the U-tube heat exchangers of the ground source heat pump, a short time step model of temperature response factor is used in a ground source heat pump system which is employed in an office building,Theoretical analysis of the U-tube heat exchanger and result compared with the experimental values are presented.The result proves that the short time step model can be used to predict heat exchange performance of the underground heat exchanger and to design and optimize a ground source heat pump system.
作者 颜爱斌 赵军
出处 《天津城市建设学院学报》 CAS 2005年第2期124-127,共4页 Journal of Tianjin Institute of Urban Construction
关键词 地源热泵 U型埋地换热器 换热性能 ground source heat pump underground U-tube heat exchanger performance of heat exchanger
  • 相关文献

参考文献5

  • 1INGERSOLL L R, ZOEBLE O J, INGERSOLL A C. Heat Conduction with Engineering Geological and Other Applications [ M ]. New York: McGraw-Hill, 1954.
  • 2KAVANAUGH S P. Simulation and experimental verification of vertical ground-coupled heat pump systems [ D ]. Oklahoma: Oklahoma State University, 1985.
  • 3ESKILSON P. Thermal analysis of heat extraction boreholes [D]. Sweden: University of Lund, 1987.
  • 4YAVUZTURK C, SPITLER J D. A short time step response factor model for vertical ground-loop heat exchangers [J].ASHRAE Transactions, 1996,105 (2) :475 - 485.
  • 5HOLMAN J P. Heat Transfer [ M ]. 9th edition. New York:McGraw-Hill, 2002.