摘要
介绍了广东省沙角A电厂5号机组烟气脱硫装置的烟气系统构成,分析了增压风机的控制策略,对5号机组烟气脱硫系统主要存在的问题、整改方案和取得的效果进行了探讨,对整改后仍存在的问题提出了改进意见。
This paper describes the structure of the flue gas system for Unit 5 flue gas desulfurization (FGD) device in Shajiao A Power Station, analyzes the control strategy of the booster fan, and approaches the existing problems, rectifying method and the results achieved on Unit 5 FGD system. Suggestions are also put forward to counter the problems still existing after the rectification.
出处
《广东电力》
2005年第5期47-50,共4页
Guangdong Electric Power
关键词
烟气脱硫
稳定调节
控制逻辑
前馈
分析
flue gas desulfurization (FGD)
stable control
control logic
feedforward
analysis