摘要
通过对妈湾发电总厂5号机组起动时水质变化的情况进行分析,指出了机组起动时影响水汽品质的因素、各水汽品质变化的规律及采取的措施,以提高机组起动时的水汽品质,并保证机组顺利起动。
This paper analyzes the water quality variations during start-up of Unit 5 in Mawan General Power Plant of SEC, indicating factors influencing steam-water quality and the rules of variations in steam-water quality during start-up of the unit. Some measures are also presented to improve the steam-water quality during start-up of the unit and to ensure the success of the start-up.
出处
《广东电力》
2005年第5期60-62,共3页
Guangdong Electric Power
关键词
机组起动
水质分析
PH值
NA^+
磷酸盐隐藏
start-up of unit
analysis of water quality
pH value
Na+