摘要 办公室内局部区域的全新风空调送风可以根本改善呼吸区域的空气品质,本文从送风系统、气流组织、能量消耗三方面阐述全新风个体送风的可行性,对个体送风末端装置的送风流场进行计算机数值模拟和预测,为经历了抗击“非典”之后的办公室空调系统提供参考数据和调整方案。 The all fresh air conditioning in some area of office can simply improve the air quality of breathing area. This paper expatiates on the feasibility of personal complete fresh air conditioning from air supply system, air current organization and energy consumption. The fluid field of air terminal device is simulated and anticipated. These analyses will offer the reference data and scheme for the office air-conditioning system after resisting SARS.
出处 《制冷与空调(四川)》 2005年第2期1-4,共4页 Refrigeration and Air Conditioning