期刊文献+

埋地输水管线牺牲阳极的阴极保护 被引量:4

Cathodic Protection of the Underground Water Pipelines
下载PDF
导出
摘要 通过对大连市引英入连输水应急工程土壤腐蚀性的现场勘察,为该工程钢质输水管网设计了牺牲阳极的阴极保护方法。30个月的实践证明,钢质输水管线经牺牲阳极的阴极保护后,整个阴极保护系统稳定,电位分布均匀,阳极保持较负的工作电位,提供较高的驱动电压,使管网处于良好的保护状态,防止了土壤的电化学腐蚀,达到了设计标准。 The cathodic protection was designed through an on-the-spot investigation of soil corrosivity to the water supply steel pipelines in the emergency project of diverting water in the Yingna River to Dalian city. Practice over 30 months indicates that the cathodic protection system keeps stable after the water supply steel pipeline was put under cathodic protection. And the potential is evenly distributed, and the working potential of the anodes has quite a relatively negative value.Thus, the system can supply a high drive potential and the pipeline is in a well-protected condition.The electrochemical corrosion is inhibited,and the design criterion is reached.
出处 《管道技术与设备》 CAS 2005年第3期40-41,共2页 Pipeline Technique and Equipment
关键词 输水管线 土壤腐蚀 阴极保护 water pipelines soil corrosion cathodic protection
  • 相关文献

参考文献7

  • 1SY/T0019—97.埋地钢质管道牺牲阳极保护设计规范.[S].,..
  • 2全国土壤腐蚀试验网站.材料土壤腐蚀试验方法[M].北京:冶金工业出版社,1993..
  • 3梁成浩,王杰,李淑英,蒋晔良.埋地管道杂散电流排流与阴极保护[J].腐蚀科学与防护技术,1998,10(2):114-117. 被引量:17
  • 4贝克曼WV.阴极保护简明手册[M].北京:石油工业出版社,1987..
  • 5GB/T17731-1999.镁合金牺牲阳极.[S].,..
  • 6SYJ23—86.埋地钢质管道阴极保护参数测定方法[Z].,..
  • 7于建华,梁成浩.钢质给水管的防腐保护实例[J].中国给水排水,2004,20(6):83-85. 被引量:1

二级参考文献6

  • 1[4]SYJ 23-86,埋地钢质管道阴极保护参数测定方法[S].
  • 2[2]全国土壤腐蚀试验网站.材料土壤腐蚀试验方法[M].北京:科学出版社,1993.
  • 3[3]GB/T 17731-1999,镁合金牺牲阳极[S].
  • 4梁成浩,化工腐蚀与防护,1994年,1卷,4页
  • 5SY/T0019-97.埋地钢质管道牺牲阳极保护设计规范.
  • 6梁成浩,王杰,李淑英,蒋晔良.埋地管道杂散电流排流与阴极保护[J].腐蚀科学与防护技术,1998,10(2):114-117. 被引量:17

共引文献18

同被引文献12

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部