In Vitro Study of Influence of Mimic Cardiac Rate on Hydrodynamics of the Different Mechanical Cardiac Valve Prostheses 被引量:2

In Vitro Study of Influence of Mimic Cardiac Rate on Hydrodynamics of the Different Mechanical Cardiac Valve Prostheses
下载PDF
导出
摘要 Objective:To assess the influe nce of mimic cardiac rate on hydrodynamics of the different mechanical prostheti c cardiac valves.Methods:US-made CarboMedics bile aflet valve and China-made Jiuling bileafle t valve and C-L tilting disc valve have been tested in a pulsatile flow simulat or in the aortic position. The testing condition was set at the mimic cardiac r ate of 55 beats/min,75 beats/min,100beats/min and a constant mimic cardiac out put of 4L/min. The mean pressure differences(ΔP),leakage volumes (LEV) and closi ng volumes(CLV) across each valve,and the effective orifice areas(EOA) have bee n analyzed.Results:Within the range of physiology, the ΔP,LEV and CLV were falling as the increasing of mimic cardiac rate,and the extent of variance was larger. The EOA was increasing with the increase of the mimic cardiac rate. It is a differe nt response as the altering of the cardiac rate for the different type of the me chanical prosthetic cardiac valves.Conclusions:The change of the mimic cardiac rate can affect the hydrodynamics of the mechanical prosthetic cardiac valves. The hydrodynamics of the bileaflet valve prosthesis is better than the tilting disc valve. Objective:To assess the influe nce of mimic cardiac rate on hydrodynamics of the different mechanical prostheti c cardiac valves.Methods:US-made CarboMedics bile aflet valve and China-made Jiuling bileafle t valve and C-L tilting disc valve have been tested in a pulsatile flow simulat or in the aortic position. The testing condition was set at the mimic cardiac r ate of 55 beats/min,75 beats/min,100beats/min and a constant mimic cardiac out put of 4L/min. The mean pressure differences(ΔP),leakage volumes (LEV) and closi ng volumes(CLV) across each valve,and the effective orifice areas(EOA) have bee n analyzed.Results:Within the range of physiology, the ΔP,LEV and CLV were falling as the increasing of mimic cardiac rate,and the extent of variance was larger. The EOA was increasing with the increase of the mimic cardiac rate. It is a differe nt response as the altering of the cardiac rate for the different type of the me chanical prosthetic cardiac valves.Conclusions:The change of the mimic cardiac rate can affect the hydrodynamics of the mechanical prosthetic cardiac valves. The hydrodynamics of the bileaflet valve prosthesis is better than the tilting disc valve.
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2005年第1期17-21,共5页 中国生物医学工程学报(英文版)
关键词 Mimic cardiac rate Mechanical prosthetic cardiac va lves HYDRODYNAMICS 心率 流体力学 心脏导管 生物医学工程
  • 相关文献

参考文献6

  • 1Reul H,van Son JAM,Steinseifer U,et al.In vitro comparison bileaflet aortic heart valve prostheses: St.Jude Medical , CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves[].Journal of Thoracic and Cardiovascular Surgery.1993
  • 2Remadi JP,Baron O,Tribouilloy C,et al.Bivalvular mechanical mitral -aortic valve replacement in 254 patients: long-term results--a 22-year follow-up[].The Annals of Thoracic Surgery.2003
  • 3CHU Yin ping 1,CHEN Ru kun 2,FAN Yu bo 3 , PU Fang 31 Department of Thoracic & Cardiovascular Surgery Second Hospital Affiliated Shanxi Medical University, Taiyuan 030001,China 2 Second Affiliated Hospital of Zhejiang University Medical.Hydrodynamics of a Newly China-Made Jiuling Bileaflet Heart Valve Prostheses[J].Chinese Journal of Biomedical Engineering(English Edition),2000,9(4):168-179. 被引量:8
  • 4Jazayeri S,Gomez MC,Tatou E,et al.Clinical experience and Doppler echocardiographic assessment of the first one hundred ATS AP ( advanced performance ) prosthetic valve in the aortic position[].Journal of Heart Valve Disease.2003
  • 5Butterfield M,Fisher J,Davies GA,et al.Comparative study of the hydrodynamic function of the CarboMedics valve[].The Annals of Thoracic Surgery.1991
  • 6Roudaut R,Roques X,Lafitte S,et al.Surgery for prosthetic valve obstruction.A single center study of 136 patients[].European Journal of Cardio Thoracic Surgery.2003

共引文献7

同被引文献46

  • 1PERNKOPF W, SAGL M, FAFILEK G. Applications of microelectrodes in impedance spectroscopy [J]. Solid State Ionics, 2005, 176(25-28): 2031-2036.
  • 2MERRILL D R, BIKSON M, JEFFERYS J C R. Electri- cal stimulation of excitable tissue: Design of efficacious and safe protocols [J]. Journal of Neuroscience Meth- ods, 2005, 141(2): 171-198.
  • 3CEDDES L A. Historical evolution of circuit models for the electrode-electrolyte interface [J]. Annals of Biomedical Engineering, 1997, 25(1): 1-14.
  • 4WEILAND J D, ANDERSON D J, HUMAYUN M S. In vitro electrical properties for iridium oxide versus tita- nium nitride stimulating electrodes [J]. IEEE Transa- tions on Biomedical Engineering, 2002, 49(12): 1574- 1579.
  • 5WALTER P, HEIMANN K. Evoked cortical potentials after electrical stimulation of the inner retina in rab- bits [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238(4): 315-318.
  • 6NADIG M N. Development of a silicon retinal implant: Cortical evoked potentials following focal stimulation of the rabbit retina with light and electricity [J]. Clin- ical Neurophysiology, 1999, 110(9): 1545-1553.
  • 7FANG X, SAKAGUCHI H, FUJIKADO T, et al. Direct stimulation of optic nerve by electrodes implanted in optic disc of rabbit eyes [J]. Graefe's Archive for Clin- ical and Experimental Ophthalmology, 2005, 243(1): 49-56.
  • 8BRUMMER S B, ROBBLEE L S, HAMBRECHT F T. Cri- teria for selecting electrodes for electrical stimulation: Theoretical and practical considerations [J]. Annals of the New York Academy of Sciences, 1983, 405(1): 159- 171.
  • 9DOBELLE W H, MLADEJOVSKY M G. Phosphenes pro- duced by electrical stimulation of human occipital cor- tex, and their application to the development of a prosthesis for the blind [J]. The Journal of Physiology, 1974, 243(2): 553-576.
  • 10TROYK P, BAK M, BERG J, et al. A model for intra- cortical visual prosthesis research [J]. Artificial Organs, 2003, 27(11): 1005-1015.

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部