摘要
通过对珠三角近几年来十几项工程约270组水泥搅拌桩载荷试验成果进行统计分析,并与国家行业标准试验要求进行比较,最后对搅拌桩复合地基承载力特征值确定方法做了进一步细化。
Through statistically analyzing about 270 groups results of static loading test on cement mixing pile related to several projects in the Pearl River delta,and comparing with the testing requirement of national standard,the paper presented a suggest about how to decide the characteristic value of subgrade bearing capacity of cement mixing pile in details.
出处
《广州建筑》
2005年第2期11-13,共3页
GUANGZHOU ARCHITECTURE
关键词
水泥搅拌桩
统计分析
载荷试验
国家行业标准
试验成果
试验要求
特征值
工程
ground treatment,cement mixing pile
static loading test
characteristic value of subgrade bearing capacity