摘要
从机组制造、结构和运行维护等方面分析了京南电厂进口贯流式机组定子线棒绝缘击穿及铁芯松动的形成原因,介绍了本厂的处理方法。
<Abstrcat> The reasons for insulation breakdown of imported bulb-type stator bar of tubular hydro set and loose of iron core were analyzed from three aspects, namely from the stand of manufacture, structure, and operation maintenance. A feasible way, which was used in Jingnan Power Plant, was presented to solve these problems.
作者
黎文明
李贤楠
LI Wen-ming, LI Xian-nan(Wuzhou Jingnan Power Plant, Guangxi, Guangxi Wuzhou 543000, China)
出处
《西北水力发电》
2005年第2期13-15,共3页
Journal of Northwest Hydroelectric Power
关键词
线棒
铁芯
电晕
热效应
贯流式机组
bar
iron core
corona
thermal effect
bulb-type tubular hydro set