摘要 针对电子线路板厂洁净房丝印区有机废气污染的问题,选择间歇式固定床活性炭吸附法净化有机废气的工艺流程,通过制冷能力和吸附量的估算,设计空塔气速为0 . 6m s,吸附剂为果壳活性炭,装填高度为1m ,分双层多个抽屉式填装,运行后,实际监测净化效果明显,苯、甲苯、二甲苯的净化效率分别为81 .5 9% ,83. 5 0 % ,85 . 4 3% ,换下的废活性炭经再生解吸后可循环使用。回收的有机溶剂掺在柴油中作为发电机的燃料。 The flowchart of the intermittent fixed be active carbon adsorption for purification of the organic waste gas was selected in accordance with the organic waste gas pollution problems from the wire printed district of the printed circuit board plant.Through the calculation ability of the causing cold and quantitites of the adsorption.some parameters of the activated carbon adsorption are designed, such as the gas velocity of the empty tower was about 0.6 m/s,the activated carbon is coconut.The activated carbon adsorption bed was designed as double story with drawers.After the adsorption bed purification,practical monitor testified: the efficient of the benzene.toluene and xylene purified to 81.59%, 83.50%, 85.43% by adsorption.The waste activated carbon was accumulated and desorption.The recycle organic products were mixed into the diesel oil to be used as fuel of motors.
出处 《环境工程》 CAS CSCD 北大核心 2005年第3期43-45,48,共4页 Environmental Engineering
基金 湖南省自然科学基金重点项目(03JJY2002)资助 湖南省科技攻关重点项目(00SSY1007)资助。
关键词 电子线路板厂 有机废气 环境污染 净化工艺 制冷能力 吸附量 organic waste gas, production of printed criculit board, activated carbon adsorption and purification
  • 相关文献

参考文献10

  • 1岑超平,古国榜.线路板生产废气的治理[J].环境科学与技术,2001,25(4):24-26. 被引量:8
  • 2郑亚南.如何通过SO14001认证[M].北京:学苑出版社,2000..
  • 3田森林,宁平.有机废气治理技术及其新进展[J].环境科学动态,2000(1):23-28. 被引量:58
  • 4杨显万,孙珮石,黄若华,黄兵,陈茂生.生物法净化低浓度挥发性有机废气研究[J].中国工程科学,2001,3(9):64-68. 被引量:33
  • 5毛国柱,闻建平,刘伟,许晓菁.生物法净化有机废气研究进展[J].现代化工,2002,22(S1):70-72. 被引量:8
  • 6P. Pichat, J. Disdier, C. Hoang-Van, ect. Purification/deolorization of indoor air and gaseous effluents by TiO2 photo-catalysis. Catalysis Today 63(2002)363~369.
  • 7(美)P.N.切雷米西诺夫 R.A.扬格主编.胡文龙等译.大气污染控制手册[M].北京:化学工业出版社,1987,5.348-355.
  • 8龚崇石 王福祥.通风空调安装手册[M].北京:中国建筑工业出版社,1989,5..
  • 9J. Prezpiorski, S. Yoshida. A. Oya. Structure of K2CO3-loaded active carbon fiber and its deodorization ability against H2S gas. Carbon 371999.1881~1890.
  • 10HO-chul shin,Jin-Won Park,Kwinam Park,et al. Removal Characteristics of Trace Compounds of Landfill Gas by Active carbon adsorption.Environmental pollution,2002. 119: 227~236.