期刊文献+

Al-Zn-In-Si-Mg合金活性溶解的临界氯离子浓度研究 被引量:1

Study on Cl^- Critical Concentration in Active Dissolution of Al-Zn-In-Si-Mg
下载PDF
导出
摘要 通过测量不同Cl-浓度下Al-Zn-In-Si-Mg合金与A3钢偶合的电偶电流、孔蚀电位、极化电阻,确定了淡水中Al-Zn-In-Si-Mg牺牲阳极活性溶解的临界Cl-浓度.实验表明,维持Al-Zn-In-Si-Mg活性溶解的临界Cl-浓度为0.05~0.15mol/L. Cl-critical concentration in active dissolution of Al-Zn-In-Si-Mg was determined by measuring the galvanic current, pit-corrosion potentials and polarization impedances. The results showed that Cl-critical concentration in dissolving Al-Zn-In-Si-Mg actively was between 0.05-0.15 molˇL-1.
出处 《大连民族学院学报》 CAS 2005年第3期66-68,共3页 Journal of Dalian Nationalities University
关键词 Al-Zn-In-Si-Mg合金 活性溶解 临界Cl^-浓度 Al-Zn-In-Si-Mg active dissolution Cl-critical concentration
  • 相关文献

参考文献4

  • 1火时中.电化学保护[M].北京:化学工业出版社,1988..
  • 2Foley R. T. Localized Corrosion of Aluminum Alloys-A Review[J]. Corrosion, 1986, 42(5): 277-288.
  • 3Mensfeld F, Hengstenberg D H. Galvanic Corrosion of Al Alloys 1. Effect of Dissimilar Metals[J]. Corrosion, 1974, 30(10): 343-353.
  • 4Reboul M. C. Galvanic Corrosion of Aluminum [J]. Corrosion, 19795, 35(9): 423-428.