1Kooi ME, Cappendijk VC. Accumulation of ultrasmall superparamagnetic particles of iron oxide in human atherosclerotic plaques: can be detected by in vivo magnetic resonance imaging. Circulation, 2003, 107:2453.
2Hozumi T, Yoshida K, Ogata Y,et al. Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography. Circulation, 1998, 97:1557.
3Schmitz SA, Coupland SE. Superparamagnetic iron oxide-enhanced MRI of stherosclerotic plaques in watanabe hereditable hyperlipidemic rabbits. Investigative Radiology, 2000, 35:460.
5Ruff J, Wiesmann F, Lanz T,et al. Magnetic resonance imaging of coronary arteries and heart valves in a living mouse: techniques and preliminary results. J Magn Reson, 2000, 146:290.
6Nahrendorf M, Wiesmann F, Hiller KH,et al. In vivo assessment of cardiac remodeling after myocardial infarction in rats by cine-magnetic resonance imaging. J Cardiovasc Magn Reson, 2000, 2:171.
7Waller C, Hiller KH, Kahler E,et al. Serial magnetic resonance imaging of microvascular remodeling in the infarcted rat heart. Circulation, 2001, 103:1564.
8Nahrendorf M, Wiesmann F, Hiller KH,et al. Serial cine-magnetic resonance imaging of left ventricular remodeling after myocardical infarction in rats. J Magn Reson Imaging, 2001, 14:547.
9Okon E, Pouliquen D, Okon P,et al. Biodegradation of magnetite dextran nanoparticles in the rat: a histologic and biophysical study. Laboratory Invest, 1994, 71:895.
10Rousseau V, Pouliquen D, Darcel F,et al. NMR investigation of experimental chemical induced brain tumors in rats, potential of a superparamagnetic contrast agent (MD3) to improve diagnosis. MAGMA, 1998, 6:13.
5Pucillo AL,Schechter AG,Moggio RA,et al.Postoperative evaluation of ascending aortic prosthetic conduits by magnetic resonance imaging[J].Chest,1990,97:106-110.
6Fattori R,Bacchi Reggiani L,Pepe G,et al.Magnetic resonance imaging evaluation of aortic elastic properties as early expression of Marfan syndrome[J].J Cardiovasc Magn Reson,2000,2:251-256.
7Metafratzi ZM,Efremidis SC,Skopelitou AS,et al.The clinical significance of aortic compliance and its assessment with magnetic resonance imaging[J].J Cardiovas Magn Reson,2002,4:481-491.
8Bansal RC,Chandrasekaran K,Ayala K,et al.Frequency and explanation of false negative diagnosis of aortic dissection by aortography and transesophageal echocardiography[J].J Am Coll Cardiol,1995,25:1393-1401.
9Cleverly JR,Barrie JR,Raymond GS,et al.Direct findings of aortic injury on contrast-enhanced CT in surgically proven traumatic aortic injury:a multicenter review[J].Clin Radiol,2002,57:281-286.
10Windecker S,Maier-Rudolph W,Bonzel T,et al.Interventional cardiology in Europe 1995[J].Eur Heart J,1999,20(7):484-495.