摘要
对现有的胸腔闭式引流装置进行改进设计,使其更加有效、方便,并增加了自体血液回输功能。经动物实验证明设计达到目的要求。
Based on the improved design of the existing thoracic cavity closed drainage system, a new multi-functional device is developed and is described here in detail. The device is more convenient and more efficient than the existing system. Besides, it has a function of autotransfusion. Animal experimental results show that it has attained the goal of the improved design.
出处
《中国医疗器械杂志》
CAS
2005年第3期215-216,共2页
Chinese Journal of Medical Instrumentation
关键词
胸腔闭式引流
胸外伤
自体血液回输
血液过滤
thoracic cavity closed drainage, chest injury, autotransfusion, hemofiltration