期刊文献+

唾液酸酶监测对细菌性阴道病诊断的价值 被引量:5

Evaluation on Determination of Bacterial Sialidase in Diagnosis of Bacterial Vaginosis
下载PDF
导出
摘要 目的探讨唾液酸酶测定法诊断细菌性阴道病的价值。方法取阴道分泌物行pH、氨试验、涂片找线索细胞,BVBlue唾液酸酶测定试验。结果BVBlue唾液酸酶试验的敏感性、特异性、阳性预期值、阴性预期值分别为92.6%,93.4%,96.2%,96.7%。BVBlue试验在检测细菌性阴道病上和传统的Amsel四步法试验相比无显著性差异,且不受阴道毛滴虫病、生殖器念珠菌病感染等的影响。结论采用BVBlue唾液酸酶测定检测细菌性阴道病简便、快速、可靠,结果易判读,是一种临床上可行的好方法。 Objective To inquire into evaluation on determining bacterial sialidase of bacteria vaginosis(BV).Methods The vaginal secretions were taken and detected by pH test,the microscopy for clue cell,BV Blue test.Results In BV test,sensitivity was 92.6%,specificity was 93.4%,positive predictive value was 96.2% and negative predictive was 96.7%.No significant difference was found in diagnosis BV Blue test and traditional four steps Amsel test.Some diseases,such as vaginal trichomoniasis,genital candidiasis,gonorrhea and mycoplasm a infection did not influence on BV Blue test.Conclusion BV Blue test in diagnosis of BV is a simple,rapid,credible,easy-reading test.
出处 《现代检验医学杂志》 CAS 2005年第3期27-28,共2页 Journal of Modern Laboratory Medicine
关键词 阴道分泌物 唾液酸酶 细菌性阴道病 诊断 vaginal secretions sialidase bacterial vaginosis diagnosis
  • 相关文献

参考文献3

  • 1Briselden A M. Sialidases (neuraminidases) in bacterial vaginosis and bacterial vaginosis-associated microflora[J]. J Clin Microbiol, 1992,30(3):663-666.
  • 2Amsel R, Totten PA. Spiegel CA,et al. Nonspecific vaginitis,diagnostic criteria and microbial epidemiologic associations [J]. AM,J Med Patri, 1983; 74:14-22.
  • 3张石革,龙振华,庄为.细菌性阴道炎与抗菌药[J].中国药房,2004,15(7):448-448. 被引量:8