摘要  通过对血泵材料的血液相容性和生物组织相容性进行了分析,并对目前常用生物材料的表面处理技术进行了比较。由于心内式血泵置入心内的特殊部位,既要保证其血液相容性,又要保证组织相容性,可采取对材料表面生物药物活性处理来实现:与血液接触材料表面,可选择r 水蛭素处理,以提高材料的血液相容性;与各种生物组织材料接触的表面,可选择纤连蛋白处理,使材料表面内皮化,以提高材料的组织相容性。 By analysis of blood compatibility and tissue compatibility of blood pump material, a comparison was given to the surface treating technology of the current commonly-used biomaterial. Owing to the particular position of micro-axial blood pump placed in heart, the active treating of bio-medicament on the material surface is used to ensure its blood and its tissue compatible. That is, r-hirudin treating is used on material interface with the blood to improve the blood compatibility; and fibronectin treating is used on the interface with various bio-tissue materials to endothelialize the surface of material and to improve its tissue compatibility.
出处 《表面技术》 EI CAS CSCD 2005年第3期61-64,共4页 Surface Technology
基金 国家自然科学基金(50275151) 湖南省自然科学基金(02JJY2080)
关键词 血泵材料 表面处理 血液相容性 组织相容性 Blood pump material Surface treating Blood compatibility Tissue compatibility
  • 相关文献

参考文献22

  • 1ISO 10993-4:2000 Biological evaluation of medical devices-Part 4:Selection of tests for interactions with blood[ S]..
  • 2孙皎,顾国珍,钱云芳.生物材料不同接触方式和条件对溶血作用影响的研究[J].生物医学工程学杂志,2003,20(1):8-10. 被引量:18
  • 3王红卫,魏永前.Ti6Al4V-TiN和Ti6Al4V-TiN-TiC生物梯度材料的血液相容性评价[J].功能材料,2000,31(4):439-441. 被引量:6
  • 4严洪海,文学军,张宁,陈关福,赵士芳.表面等离子渗氮处理钛的生物相容性评价 5.体内植入研究[J].中国口腔种植学杂志,1997,2(2):59-63. 被引量:5
  • 5Laing P G, Fergason A B, Hodge E S, et al. Tissue reaction in rabbit muscle exposed to metallic implants. [J] J. Biomed. Mater. Res, 1967,1:135.
  • 6Park J B. Tissue response to implants. In ( Park J. B. Bio-materials science and engineering, Chapter 7)New York: Plenum Press, 1984:171 ~191.
  • 7Ungersbock A, Pohler O, Perren S. M, et al. Evaluation of the soft tissue interface at titanium implants with different surface treatments: experiment study on rabbits[J]. Bio-Med. Mat. Eng, 1994, 4:317.
  • 8Tayama E,Hayashida N,Akasu K, et al. Biocompatibility of heparin-coated extracorporeal bypass circuits: new heparin bonded bioline system [J].Artif Organs, 2000, 24(8) :618 ~ 623.
  • 9Hayashi Y, Hotake S, Sawa Y, et al. Percutaneous car-diopulmonary support with heparin-coated circuits in post-cardiotomy cardiogenic shock [J].Jpn J Thorac Cardiovasc Surg, 2000, 48(5) :274 ~ 279.
  • 10Kong Xiangqing, Effect of biologically active coating on biocompatibility of Nitinol devices designed for the closure of intra-atrial communications, Biomaterials, 2002, 23:1775 ~ 1783.

二级参考文献59

  • 1叶裕中,程佩珞,金宗德,王英华.Ni-ZrO_2复合镀层的形成及其高温氧化性能[J].电镀与精饰,1993,15(1):9-13. 被引量:4
  • 2汤宝寅.等离子体源离子注入(I)──原理和技术[J].物理,1994,23(1):41-45. 被引量:22
  • 3汪泓宏 田明波.离子束表面强化[M].北京:机械工业出版社,1992..
  • 4松村宗顺.-[J].金属表面技术,1985,36(1):442-451.
  • 5陈菲 江晨 王周成 等.钛基表面电泳沉积纳米羟基磷灰石生物陶瓷涂层[A]..第十一次全国电化学会议论文集[C].中国南京,2001.F026.
  • 6卢燕平.能手表面防蚀处理[M].北京:冶金工业出版社,1995..
  • 7[1]ISO 10993-4:2000 Biological evaluation of medical devices--Part 4: Selection of tests for interactions with blood
  • 8[2]ISO/TR 7405-1984(E):Hemolysis test (in vitro test directly on materials)
  • 9[3]ISO 10993-12:1992 Biological evaluation of medical devices--Part 12:Sample preparation and reference materials
  • 10[4]ISO 10993-5:1992 Biological evaluation of medical devices--Part 5: Tests for cytotoxicity: in vitro methods

共引文献101

同被引文献49

引证文献3

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部