摘要
以300 MW机组为例,定量分析了凝结水过冷却对机组热经济的影响,介绍了控制和消除凝结水过冷却度的措施,以提高机组安全经济运行水平。
Analysis of the thermal economical effect of the condensate super-cooling onto the generating unit has quanti-tively been made in this paper taking 300 MW unit as an example. The countermeasures of controlling and removing condensate super-cooling has also been presented so as to raise the operating efficiency of the unit.
出处
《电站辅机》
2005年第2期11-13,共3页
Power Station Auxiliary Equipment
关键词
凝结水过冷却
热经济性
分析
措施
condensate super-cooling
thermal economy
analysis
countermeasure.