阐述变压器油中氢气含量增高形成机理。对牡丹江电厂5号低压厂用变压器油中氢气含量异常的原因进行了分析,提出了防止变压器油中氢气含量增高的技术措施。
The forming mechanism of hydrogen content increased in the transformer oil was described. The causes for hydrogen content abnormal in the oil of No.5 low-voltage auxiliary transformer in Mudanjiang No.2 power generation plant were analyzed, and the technical measures to prevent against hydrogen content increasing in the transformer oil was suggested in the paper.