摘要
针对HR9-040-5型离心空压机出现的喘振现象进行了分析研究,得出主要原因是空气冷却器故障。改变了冷却器结构形式并采取了防范措施。
Analysis reasearch is carried out on phenomenon of surge in HR9-040-5 type centrifugal air compressor, and the reason is air cooler with trouble. The structure form of cooler is changed and prevent measures is taken.
出处
《风机技术》
2005年第3期51-53,共3页
Chinese Journal of Turbomachinery