摘要 通过对SPECT中各种常用滤波函数的数学分析、模型试验和临床应用的比较.认为Butterworth滤波器确为SPECT最佳的重建滤波函数.经过两年来的临床证实,如果在重建前应用多功能的Gausian滤波器作预处理,能进一步增强图像的对比度,提高信噪比,从而获得分辨率更高的SPECT图像.改变Gausian函数的三参数S、fc和n,可达到多种不同的滤波效果,因此重建前滤波首选Gausian滤波器.同时对如何选择Gausian滤波器的参数及临床应用的最佳条件进行了阐述. Abstract SPECT is a very useful imaging equipment for medical diagnosis. In order to get high quality images, we must put emphasis on filter selection as well as routine quality control. Through mathematical analysis, phantom test and clinical verification, we proved Butterworth filter to be a flexible and efficient one for backprojection reconstruction. Iterative reconstruction is a much precise method but it takes much longer time to Perform. We found that another practical method to obtain higher resolution, lower noise 3-D slices if we applied Gausian filter to raw data prior to the backprojection process. Gausian filter, with three selectable parameters, could not only enhance but also filter images.
出处 《中华核医学杂志》 CAS CSCD 北大核心 1994年第3期161-163,T011,共4页 Chinese Journal of Nuclear Medicine
  • 相关文献

参考文献1

  • 1陈盛祖,中华核医学杂志,1991年,2卷,104页

同被引文献37

  • 1杨民,路宏年,傅健.基于卷积反投影CT重建的一种新型实用滤波函数[J].CT理论与应用研究(中英文),2000,9(z1):29-32. 被引量:6
  • 2赵周社,周前.Metz滤波函数在SPECT图像重建中的参数选择[J].核技术,1993,16(5):286-290. 被引量:1
  • 3卢献平,莫丽君.不同滤波函数对^99mTc—MIBI心肌SPECT图像的影响[J].中华核医学杂志,1993,13(2):104-105. 被引量:2
  • 4杜艳,杨敏福,田月琴,方纬,沈锐,何作祥.门控心肌SPECT显像三种定量分析软件测定左心室容积和射血分数的比较[J].中华核医学杂志,2007,27(3):161-164. 被引量:11
  • 5Van Laere K, Koole M, Lemahieu I, et al. Image filtering in single - photon emission computed tomography: principles and applications. Comput Med Imaging Graph, 2001, 25: 127-33.
  • 6Bitarafan A, Rajabi H. The effect of filtrating and reconstruction method on the left ventricular ejection fraction derived from GSPET- a statistical comparison of angiography and echocardiography. Ann Nucl Med, 2008, 22: 707- 713.
  • 7Starck SA, Ohlsson J, Carlsson S. An evaluation of reconstruction techniques and scatter correction in bone SPECT of the spine. Nucl Med Commun, 2003, 24:565 - 570.
  • 8Gilland DR, Tsui BM, McCartney WH, et al. Determination of the optimum filter function for SPECT imaging. J Nuel Med, 1988, 29: 643-650.
  • 9Brambilla M, Cannillo B, Dominietto M, et al. Characterization of ordered - subsets expectation maximization with 3D post - reconstruction Gauss filtering and compdrison with filtered backprojection in 99m TC SPECT. Annals of Nuclear Medicine, 2005, 19, 75- 82.
  • 10Vera P,Manrique A,Pontvianne V,et al.Thallium-gated SPECT in patients with major myocardial infarction:effect of filtering and zooming in comparison with equilibrium radionuclide imaging and left ventriculography.J Nucl Med,1999,40:513-521.

引证文献6

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部