A Novel Biomolecular Immobilization Matrix Based on Nanoporous ZnO/Chitosan Composite Film for Amperometric Hydrogen Peroxide Biosensor
A Novel Biomolecular Immobilization Matrix Based on Nanoporous ZnO/Chitosan Composite Film for Amperometric Hydrogen Peroxide Biosensor
基金
This work was supported by the National Natural Science Foundation of China(Grants No.20075006,29975006,20375012)
the Foundation for Ph.D.Thesis Research(No.20010532008)
the Foundation of Science Commission of Yunnan Province(No.2002B0033M).
参考文献7
-
1Y. Liu, T. Yu, Macromol. Chem. Phys., 1997, C37, 459.
-
2X. Chen, S. J. Dong, Biosens. Bioelectron., 2003, 18, 999.
-
3M. Ah .Kim, W. Y. Lee, Anal. Chim. Acta, 2003, 479, 143.
-
4G. Wang, J. J. Xu, H. Y. Chen, Z. H. Lu, Biosens. Bioelectron., 2003, 18, 335.
-
5Y.Q. Miao, S. W. Tan, Anaylst, 2000, 125, 1591.
-
6E. Topoglidis, A. E. G. Cass, B. O'Regan, J. R. Durrant, J. Electroanal. Chem., 2001, 517, 20.
-
7B. Wang, B. Li, Q. Deng, S. J. Dong, Anal. Chem., 1998, 70, 3170.
-
1JuanZHANG ShengYiZHANG JingJuanXU HongYuanCHEN.A New Method for the Synthesis of Selenium Nanoparticles and the Application to Construction of H_2O_2 Biosensor[J].Chinese Chemical Letters,2004,15(11):1345-1348. 被引量:7
-
2Furkan Yalcner,Emre Cevik,Mehmet Senel,Abdulhadi Baykal.Development of an Amperometric Hydrogen Peroxide Biosensor based on the Immobilization of Horseradish Peroxidase onto Nickel Ferrite Nanoparticle-Chitosan Composite[J].Nano-Micro Letters,2011,3(2):91-98. 被引量:2
-
3Amperometric Glucose Sensor with Tetrathiafulvalene as an Electron Transfer Mediator[J].Chemical Research in Chinese Universities,1995,11(3):189-194.
-
4MA RongNa,WANG Bin,LIU Yan,LI Jing,ZHAO Qian,WANG GuoTao,JIA WenLi,WANG HuaiSheng.Direct electrochemistry of glucose oxidase on the hydroxyapatite/Nafion composite film modified electrode and its application for glucose biosensing[J].Science China Chemistry,2009,52(11):2013-2019. 被引量:3
-
5D.R.Shobha Jeykumari,R.Kalaivani,S.Sriman Narayanan.Nanobiocomposite Electrochemical Biosensor Utilizing Synergic Action of Neutral Red Functionalized Carbon Nanotubes[J].Nano-Micro Letters,2012,4(4):220-227. 被引量:2
-
6Fa Ming TIAN,Bo XU,Guo Yi ZHU.A Hydrogen Peroxide Biosensor Combined HRP Doped Polypyrrole with Ferrocene Modified Sol-gel Derived Composite Carbon Electrode[J].Chinese Chemical Letters,2001,12(7):625-628.
-
7LI Feng,WANG Zhen,FENG Yan.Construction of bienzyme biosensors based on combination of the one-step electrodeposition and covalent-coupled sol-gel process[J].Science China Chemistry,2009,52(12):2269-2274. 被引量:1
-
8黎雪莲,袁若,柴雅琴,王娜,朱强.基于溶胶-凝胶化的普鲁士蓝/纳米金修饰铂电极的辣根过氧化物酶传感器(英文)[J].西南师范大学学报(自然科学版),2005,30(5):862-867. 被引量:2
-
9第十届世界生物传感器大会将在上海召开[J].物理化学学报,2007,23(9):1320-1320.
-
10ZHANG Jin-lei,TAN Xue-cai,ZHAO Dan-dan,TAN Sheng-wei,HUANG Zeng-wei,MI Yan,HUANG Zai-yin.Amperometric Hydrogen Peroxide Biosensor Based on Multiwall Carbon Nanotubes and Cadmium Sulfide Quantum Dots[J].Chemical Research in Chinese Universities,2010,26(4):541-545. 被引量:1