期刊文献+

国产可吸收螺钉治疗内踝骨折47例临床分析 被引量:5

Absorbable screw(PDLLA)in the treatment of 47 cases of medial malleolus fracture
下载PDF
导出
摘要 目的观察国产可吸收螺钉治疗内踝骨折的疗效及并发症.方法对47例采用国产可吸收螺钉固定的内踝骨折患者的临床资料及诊治情况进行回顾性分析.结果随访5~34个月,全部骨折愈合良好,无感染、积液等并发症,术中有3例共3枚螺钉断裂,需再次钻孔植入.结论国产可吸收螺钉治疗内踝骨折有利于骨折愈合,不需二次取内固定手术.但抗扭力不足,需要改进. Objective To evaluate the efficacy and complications of absorbable screw(poly DL-Lactide acid, PDLLA)in the treatment of medial malleolus fracture.Methods Ninety-four PDLLA screws were used in 47 cases of medial malleolus fractures.Fracture healing and complications were observed.Results All fractures were healed with excellent or good function and no infection and exudation happened after a mean of 5 to 34 months′ follow-up. There are 3 screws broken during inserting and need to replanting.Conclusion The efficacy of PDLLA screws in treating medial malleolus fracture were reliable with better biocompatibility, it contributes to fracture′s healing. But its biomechanical property needs to be improved.
出处 《重庆医学》 CAS CSCD 2005年第7期984-985,共2页 Chongqing medicine
关键词 骨折 固定 内踝 fracture fixation medial malleolus
  • 相关文献

参考文献9

  • 1Rokkanen P, Bostman O, Vainiopaa S. Biodegradable implants in fracture fixation: early results of treatment of the ankle[J]. Lancet, 1985,1(6):1422
  • 2吴雪晖,许建中,李起鸿,杨柳,王序全,谭祖键,马树支,周强.国产可吸收螺钉在新鲜骨折端的临床应用[J].中华创伤杂志,2004,20(6):373-374. 被引量:8
  • 3郑万平.骨片钉治疗踝关节骨折12例报道[J].重庆医学,2004,33(12):1858-1859. 被引量:7
  • 4Partio EK, Bostman O, Hivensalo E. Self-reinforced absorbable screws in the fixation of displaced ankle fracture: a prospective clinical study of 152 patients[J]. J Orthop Trauma,1992, 6(2) :209
  • 5Nordstrom P, Pohjonen T, Tormala P, et al. Shear-load carrying capacity of cancellous bone after implantation of self-reinforced polyglycolic acid and poly-L-lactic acid pins: experimental study on rats[J]. Biomaterials, 2001,22(18): 2557
  • 6Jukkala PK, Laitinen O, Vasenius J, et al. Healing of subcapital femoral osteotomies fixed with self-reinforced poly-L-lactide screws: an experimental long-term study in sheep[J]. Arch Orthop Truama Serg,2002,122(6): 360
  • 7Tuompo P, Paritio EK, Patiala H, et al. Causes of the clinical tissue response to polyglycolide and polylactide implants with an emphasis on the knee[J]. Arch Orthop Truama Surg, 2001,121 (5): 261
  • 8Juutilainen T, Hirvensalo E, Partio EK, et al. Complications in the first 1043 operations where self-reinforced poly-L-lactide implants were used solely for tissue fixation in orthopaedics and traumatology[J]. Int Orthop, 2002,26(2):122
  • 9Thordarson DB, Hurvitz G. PLA screw fixation of Lisfranc injuries[J]. Foot Ankle Int, 2002,23 ( 11 ): 1003

二级参考文献6

  • 1Giovanni De,Bastiani A,Graham A,et al.Orthofix external fixation in trauma and orthopaedics[J].Springer,2000,9:392
  • 2Asnis SE,Emberg JJ,Bostrom MP,et al.Cancellous bone screw thread design and holding power[J].J Orthop Trauma,1996,10:462
  • 3Rokkanen P, Bostman O, Vainionpaa S, et al. Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle. Lancet, 1985, 1:1422-1424.
  • 4Partio EK, Bostman O, Hirvensalo E, et al. Self-reinforced absorbable screws in the fixation of displaced ankle fracture: a prospective clinical study of 152 patients. J Orthop Trauma, 1992, 6: 209-215.
  • 5Nordstrom P, Pohjonen T, Tormala P, et al. Shear-load carrying capacity of cancellous bone after implantation of self-reinforced polyglycolic acid and poly-L-lactic acid pins: experimental study on rats. Biomaterials, 2001, 22: 2557 - 2561.
  • 6Thordarson DB, Hurvitz G. PLA screw fixation of Lisfranc injuries. Foot Ankle Int, 2002, 23:1003 - 1007.

共引文献13