期刊文献+

界面折射率不一致对显微成像穿透深度的限制

Limit Penetration Depth of Microscopic Imaging Caused by Focusing Light Into the Bulk Specimen Through Planar Interfaces Between Materials of Mismatched Refractive Index
下载PDF
导出
摘要 在运用共焦显微术及低相干显微成像术等进行光学断层成像时,要将光束聚焦到样品内部以便实现光学断层成像,然而由于生物组织等的折射率与盖玻璃以及浸液不同,因而会引入很大的球差,从而使入射电磁波发生畸变.分析了由于多层折射率不一致而引入的球差的大小,并运用所得的公式计算了折射率不一致对光在样品中穿透深度及焦面附近光场分布的影响. Applications of confocal scanning microscopy and low coherence tomography in the biological and material sciences for optical-sectioning imaging require focusing light into the bulk specimen. However, the differences of refractive indices among biological tissues, the cover slip and immersion medium cause the strong spherical aberration and make the electromagnetic distribution in the focal region distorted. The spherical aberrations caused by focusing the light deeply into the specimen through multilayer medium with different refractive index are analyzed. The results are used to calculate the limit penetration depth of microscopic imaging caused by focusing light into the bulk specimen through planar interfaces between materials of mismatched refractive index. The effect of spherical aberration on electromagnetic distribution in the focal region is also discussed.
出处 《光子学报》 EI CAS CSCD 北大核心 2005年第6期814-816,共3页 Acta Photonica Sinica
基金 苏州大学现代光学技术省重点实验室开放课题(项目号:KJS01002) 南京理工大学青年基金(Njust200302)资助
关键词 折射率 显微成像 穿透深度 Mismatched refractive Microscopy Penetration depth
  • 相关文献

参考文献8

  • 1Sheppard C J R,Cogswell C J.Effects of aberrating layers and tube length on confocal imaging properties.Optik ,1991, 87(1):34~38
  • 2Schmitt J M,Kniittel AYadlowsky M.Confocal microscopy in turbid media.J Opt Soc Am A,1994,11(8):2226~2235
  • 3Smithpeter C L,Dunn A K,Welch A J,et al.Penetration depth limits of in vivo confocal reflectance imaging. Applied Optics,1998,37(13):2749~2754
  • 4Sheppard C J R,Mattews H J.Imaging in high aperture optical systems. J Opt Soc Am A,1987,4(4):1354~1360
  • 5Sacconi L,Froner E,Antolini R,et al.Multiphoton multifocal microscopy exploiting a diffractive optical element.Optics Letters,2003,28(20):1918~1920
  • 6Jelda Jayne Miranda,Caesar Saloma.Four-dimensional microscopy of defects in untegrated circuits.Applied Optics,2003,42(32):6520~6524
  • 7Podoleanu A G,Dobre G M,Cucu R G,et al.Sequential optical coherence tomography and confocal imaging.Optics Letters,2004,29(4):364~367
  • 8高万荣,陶纯堪,杨晓春.共焦扫描显微成象的光学断层平面分辨率与信噪比之间的关系[J].光子学报,2002,31(6):730-735. 被引量:7

二级参考文献9

  • 1Smithepter C L,Dunn A K,Welch A J,et al.Penetration depth limits of in vivo confocal relection imaging[].Applied Optics.1998
  • 2Kimura S,Munakata C.Dependence of 3-D optical transfer functions on the pinhole radius in a fluorescent confocal optical microscope[].Applied Optics.1990
  • 3Cox I J,Sheppard C J R,Wilson T.Super -resolution by confocal fluorescent microscopy[].Optik.1982
  • 4Sandison D R,Webb W W.Background rejection and signal -to-noise optimization in confocal and alternative fluorescence microscopes[].Applied Optics.1994
  • 5Rajadhyaksha M,RoxAnderson R,Webb R H.Video-rate confocal scanning laser microscope for imaging human tissues in vivo[].Applied Optics.1999
  • 6Kimura S,Munakata C.Calculation of three-dimensional optical transfer function for a confocal scanning fluorescent microscope[].Journal of the Optical Society of America.1989
  • 7Fried D L.Resolution, signal -to-noise-ratio, and measurement precision[].Journal of the Optical Society of America.1979
  • 8Ronchi V.Resolving power of calculated and detected images[].Journal of the Optical Society of America.1961
  • 9Fried D L.Resolution, signal -to-noise-ratio, and measurement precision, addendum[].Journal of the Optical Society of America.1980