摘要 在日光温室设计中,建筑参数的选择要考虑温室建造成本、室内透光量、保温性能、冬季燃料费用、结构承载力、使用年限、土地利用率等因素。采用多目标模糊决策法对沈阳地区跨度7.5m、后坡长度2.0m、后坡仰角在25°~45°之间变化的不同日光温室建筑参数方案进行了优选。结果显示,围护结构材料相同、建筑参数不同的8个方案中跨度7.5m、后坡长度2.0m、后墙高2.2m、脊高3.7m的温室最优。 Cost and performance of a greenhouse should be considered in determination of building parameters of a solar greenhouse. The method of multi-objective fuzzy optimization was adopted to optimize the building parameters of greenhouses with constant parameters of span 7.5 m, north slope length 2.0 m and north slope angle 25°-45° in Shenyang city. The results show that the optimum building parameters, among the group A with ridge height 3.7 m, north wall height 2.4 m, 2.2 m, 2.0 m and 1.8 m respectively and the group B with north wall height 2.2 m, ridge height 3.3 m, 3.5 m, 3.7 m and 3.9 m respectively, are span 7.5 m, north slope length 2.0 m, north wall height 2.2 m and ridge height 3.7 m.
出处 《农业机械学报》 EI CAS CSCD 北大核心 2005年第7期108-110,共3页 Transactions of the Chinese Society for Agricultural Machinery
关键词 日光温室 建筑参数 多目标模糊决策 Solar greenhouse, Building parameters, Multi-objective fuzzy decision
  • 相关文献

参考文献5

  • 1Meng Shaochun, Wang Tieliang. The characteristics of energy-saving greenhouse of northeast China (Type LiaoshenI). '98沈阳21世纪东北亚农业发展国际会议论文集. 沈阳:辽宁民族出版社,1998.
  • 2刘文合.经济型日光温室设计研究:[硕士学位论文]. 沈阳:沈阳农业大学,2002.
  • 3周长吉,孙山,吴德让.日光温室前屋面采光性能的优化[J].农业工程学报,1993,9(4):58-61. 被引量:41
  • 4佟国红,王铁良,白义奎,刘文合.日光温室建筑参数对室内温度环境的影响[J].沈阳农业大学学报,2003,34(3):203-206. 被引量:9
  • 5王铁良 孟少春.单坡温室设计与建造[M].沈阳:辽宁科学技术出版社,2003..