期刊文献+

Short-term survival analysis of the all-polyethylene tibial component in total knee arthroplasty

Short-term survival analysis of the all-polyethylene tibial component in total knee arthroplasty
原文传递
导出
摘要 Objective: To report the clinical and radiological results of 24 total knee arthroplasty in which all-polyethylene tibial components were used. Methods: Between December 2000 and December 2002, 24 cemented total knee arthroplasty in 21 patients were performed using all-polyethylene tibial components. The mean age of the 21 patients (9 men and 12 women) at operation was 55 years, ranging 48-61 years. The mean preoperative hospital for special surgery (HSS)score was 40.2 (range, 36-43). The diagnoses were degenerative osteoarthritis in 15 patients, rheumatoid arthritis in 5 and traumatic arthritis in 1. All the operations were performed by the same surgeon group and there were unilateral operations in 18 patients and bilateral operations in 3. Results: Eighteen patients were followed up with a follow-up rate of 85.7%. The mean follow-up is 2.5 years (range, 1-3 years) and mean postoperative HSS scores was 87.5 (range, 83-89). Among them, 18 were excellent, 3 good, 3 poor and none was fair (the results of three lost patients were classified as poor). Of those reviewed, the prosthesis was all in situ and no revision occurred. Radiological assessment of these patients revealed 4 ( 16.67%) tibial components with radiolucent lines (mean width≤2 mm) distributed mainly in zone 1 and zone 4. None of these knees was symptomatic. Conclusions: The result of total knee arthroplasty using all-polyethylene tibial components is encouraging. The operative techniques are similar to those in arthroplasty using metal-backed tibial component.
出处 《Chinese Journal of Traumatology》 CAS 2005年第2期126-128,共3页 中华创伤杂志(英文版)
关键词 Arthroplsty replacement knee POLYETHYLENE Prostheses and implants FOLLOW-UP 聚乙烯 胫骨结构 膝盖关节成形术 生存质量
  • 相关文献

参考文献8

  • 1Forster MC,Kothari P,Howard PW.Minimum 5 -year follow-up and radiologic analysis of the all-polyethylene tibial component of the Kinemax Plus system[].Journal of Arthroplasty.2002
  • 2Hart WJ.All-polyethylene compared with metal-backed tibial components in total knee arthroplasty[].Journal of Bone and Joint Surgery British Volume.2003
  • 3Ito J,Koshino T,Okamoto R,et al.15 -year follow-up study of total knee arthroplasty in patients with rheumatoid arthritis[].Journal of Arthroplasty.2003
  • 4Kelly MA,Clarke HD.Long-term results of posterior cruciate-substituting total knee arthroplasty[].Clinical Orthopaedics.2002
  • 5Muratoglu OK,Mark A,Vittetoe DA,et al.Polyethylene damage in total knees and use of highly crosslinked polyethylene[].Journal of Bone and Joint Surgery British Volume.2003
  • 6Minoda Y,Kobayashi A,Iwaki H,et al.Polyethylene wear particles in synovial fluid after total knee arthroplasty[].Clinical Orthopaedics.2003
  • 7Cope MR,O Brien BS,Nanu AM.The influence of the posterior cruciate ligament in the maintenance of joint line in primary total knee arthroplasty: a radiologic study[].Journal of Arthroplasty.2002
  • 8Freeman MA,MacInnes T,Revell PA.The histology of" reactive lines" in well-fixed components[].Journal of Arthroplasty.2003

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部