摘要
基于抗坏血酸还原铜(Ⅱ),而用新亚铜试剂-分光光度法测定新生的铜(Ⅰ),籍以间接测定制剂中的抗坏血酸含量,其结果与碘量法一致。
Ascorbic acid (VC) in preparations was determined by indirect spectrophotometry, based on the color formation of Cu(I)-neocuproine complex from neocuproine and Cu (II) which could be reduced by VC. The results obtained were in good agreement with the iodine titration method.
出处
《中国医药工业杂志》
CAS
CSCD
北大核心
1995年第4期165-166,共2页
Chinese Journal of Pharmaceuticals
关键词
抗坏血酸
新亚铜试剂
分光光度法
测定
ascorbic acid, neocuproine,spectrophotometry, determination